Key result
Semi-automated 3D transesophageal echocardiography highly correlated with multi-slice computed tomography for aortic annular diameters (r=0.96, p<0.0001) in patients planned for TAVR.
Why the study?
Accurate aortic annulus measurements are essential for TAVR prosthesis sizing, but the gold standard MSCT might be contraindicated in some patients.
Does three-dimensional transesophageal echocardiography correlate with multi-slice computed tomography for aortic annulus sizing in patients undergoing TAVR?
Observational (n=39)
No
Does three-dimensional transesophageal echocardiography correlate with multi-slice computed tomography for aortic annulus sizing in patients undergoing TAVR?
Effect estimate: r=0.96
p-value: p=<0.0001
Semi-automated and manual 3D TEE provide aortic annulus measurements comparable to MSCT, offering a reliable alternative for TAVR planning when MSCT is contraindicated.
3D TEE may offer alternative annulus sizing when MSCT contraindicated; leaves open prospective outcome validation before practice change.
Background In transcatheter aortic valve replacement (TAVR), accurate aortic annulus measurements are essential for prosthesis sizing to ensure procedural success. Although multi-slice computed tomography (MSCT) is considered the gold standard for aortic annulus measurement pre TAVR, MSCT might be contraindicated in some patients. Aim In patients undergoing TAVR, we sought to correlate manual and newer semi-automated three-dimensional (3D) transesophageal echocardiography (TEE) aortic annular measurements to MSCT measurements. In addition, we assessed the reproducibility of these 3D TEE methods. Methods Retrospective, single centre trial involving 39 patients with severe symptomatic aortic stenosis (AS) planned for TAVR, who underwent both pre-procedural MSCT and pre/peri- procedural manual and semi-automated 3D TEE. Results Mean age was 85.3 ± 4.7 years. Both 3D TEE methods highly correlated with MSCT for annular diameters (semi-automated r =0.96, p<0.0001 and manual r=0.84, p<0.0001) and for annular areas (semi-automated r=0.96, p<0.0001 and manual r=0.82, p<0.0001). Inter-observer reproducibility was high for both 3D TEE methods for annular diameters (semi-automated r=0.96, p<0.001 and manual r=0.91, p<0.001) and annular area (semi-automated r=0.96, p<0.0001 and manual was 0.95 p<0.0001). Conclusion Both semi-automated and manual 3D TEE for sizing of the aortic annulus for TAVR is comparable to MSCT. 3D TEE methods are easily reproducible. Newer semi-automated 3D TEE has the best correlation to MSCT. 3D TEE is an excellent alternative imaging modality for TAVR planning in patients whom MSCT is contraindicated.
No takes yet. Share an insight, caveat, or question.
Mugwagwa et al. (2020) conducted an observational in Severe symptomatic aortic stenosis (n=39). Three-dimensional transesophageal echocardiography (3D TEE) vs. Multi-slice computed tomography (MSCT) was evaluated on Correlation of aortic annular diameters (r=0.96, p=<0.0001). Semi-automated 3D transesophageal echocardiography highly correlated with multi-slice computed tomography for aortic annular diameters (r=0.96, p<0.0001) in patients planned for TAVR.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: