Why the study?
To evaluate the agreement between novel automated software of 3D-TEE and MDCT for aortic annular measurements in preprocedural TAVR.
Does 3D-TEE using novel automated software agree with MDCT for aortic annular measurements in patients undergoing preprocedural TAVR evaluation?
Does 3D-TEE using novel automated software agree with MDCT for aortic annular measurements in patients undergoing preprocedural TAVR evaluation?
Automated 3D-TEE software provides aortic annular measurements that correlate strongly with MDCT, suggesting it is a feasible alternative for TAVR sizing.
Answers are grounded in this paper and cite their sources.
May reduce MDCT reliance for TAVR planning; confirms automated 3D-TEE agreement in meta-analysis.
(1) Background: We performed this study to evaluate the agreement between novel automated software of three-dimensional transesophageal echocardiography (3D-TEE) and multidetector computed tomography (MDCT) for aortic annular measurements of preprocedural transcatheter aortic valve replacement (TAVR); (2) Methods: PubMed, EMBASE, Web of Science, and Cochrane Library (Wiley) databases were systematically searched for studies that compared 3D-TEE and MDCT as the reference standard for aortic annular measurement of the following parameters: annular area, annular perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter. Meta-analytic methods were utilized to determine the pooled correlations and mean differences between 3D-TEE and MDCT. Heterogeneity and publication bias were also assessed. Meta-regression analyses were performed based on the potential factors affecting the correlation of aortic annular area; (3) Results: A total of 889 patients from 10 studies were included in the meta-analysis. Pooled correlation coefficients between 3D-TEE and MDCT of annulus area, perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter measurements were strong 0.89 (95% CI: 0.84–0.92), 0.88 (95% CI: 0.83–0.92), 0.87 (95% CI: 0.77–0.93), 0.87 (95% CI: 0.77–0.93), 0.79 (95% CI: 0.64–0.87), and 0.75 (95% CI: 0.61–0.84) (Overall p < 0.0001), respectively. Pooled mean differences between 3D-TEE and MDCT of annulus area, perimeter, area derived-diameter, perimeter derived-diameter, maximum and minimum diameter measurements were −20.01 mm2 ((95% CI: −35.37 to −0.64), p = 0.011), −2.31 mm ((95% CI: −3.31 to −1.31), p < 0.0001), −0.22 mm ((95% CI: −0.73 to 0.29), p = 0.40), −0.47 mm ((95% CI: −1.06 to 0.12), p = 0.12), −1.36 mm ((95% CI: −2.43 to −0.30), p = 0.012), and 0.31 mm ((95% CI: −0.15 to 0.77), p = 0.18), respectively. There were no statistically significant associations with the baseline patient characteristics of sex, age, left ventricular ejection fraction, mean transaortic gradient, and aortic valve area to the correlation between 3D-TEE and MDCT for aortic annular area sizing; (4) Conclusions: The present study implies that 3D-TEE using novel software tools, automatically analysis, is feasible to MDCT for annulus sizing in clinical practice.
No takes yet. Share an insight, caveat, or question.
Mork et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: