Why the study?
Does 3D-TEE improve aortic annulus sizing and prosthesis selection compared to 2D-TEE in patients undergoing TAVI?
Does 3D-TEE improve aortic annulus sizing and prosthesis selection compared to 2D-TEE in patients undergoing TAVI?
3D-TEE yields significantly larger aortic annulus dimensions than 2D-TEE, altering prosthesis size selection in 40% of patients and potentially reducing undersizing in TAVI.
Answers are grounded in this paper and cite their sources.
May warrant 3D-TEE for annulus sizing in TAVI; leaves open effects on outcomes versus 2D-TEE.
PURPOSE: The assessment of aortic annular size is critical, and inappropriate sizing is thought to be a main reason of paravalvular aortic regurgitation. Multidetector computed tomograph is associated with the risk of contrast nephropathy. For optimal evaluation of the complex structure of the aortic annulus, three-dimensional (3D)-methods should be used. We therefore sought to determine the value of 3D-transoesophageal echocardiography (3D-TEE) for appropriate sizing. METHODS: Hundred and one patients (mean age 81·4 years) with symptomatic aortic valve stenosis (AS) and high surgical risk profile (mean log. EuroScore 28·8%) being scheduled for transcatheter aortic valve implantation (TAVI) were included. 2D- and 3D-TEE were performed before the procedure to evaluate the aortic annulus diameter. RESULTS: Maximum, minimum and mean (max diameter + min diameter/2) annulus diameters were 24·7, 23·1 and 23. 9 mm in 3D-TEE and compared to 22·6 mm in 2D-TEE (P<0·001; 0·07; <0·001). The interobserver variability for 3D-TEE was low with a mean difference of 0·18 mm compared to 2D-TEE with 0·59 mm. The application of 3D-TEE caused a change of prosthesis size selection in 40% of patients compared to 2D-TEE. In this study, we implanted three different types of catheter-mounted valves (Edwards-SAPIEN(™) XT valve, CoreValve(™) and JenaValve(™) ). Final angiography confirmed valve competence (mild insufficiency) in 91%, and there was no aortic regurgitation greater than moderate in the follow-up echocardiographic evaluation. CONCLUSION: Assessment of aortic annulus dimensions for TAVI size selection can safely be performed with 3D-TEE only. Based on our results with significantly higher annulus diameter compared to 2D-TEE, we recommend 3D-TEE to reduce prosthesis undersizing.
No takes yet. Share an insight, caveat, or question.
Kretzschmar et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: