Answers are grounded in this paper and cite their sources.
This paper presents a framework for malicious corruption resilience in phasor measurement unit (PMU) data and a methodology for applying this in wide-area damping control. The problem of detecting corruptions in raw PMU measurements is formulated as a compressed sensing problem and the compromised signals are recovered using an lp-norm (0 <; p <; 1)-based online robust principal component analysis (RPCA) algorithm. The performance of the proposed method has been compared for different patterns of corruption with an l1-norm-based RPCA algorithm. The effectiveness of using the proposed data preprocessing architecture for correcting raw PMU feedback signals corrupted by missing data attack was demonstrated for closed-loop wide-area power oscillation damping control in 16-machine, 5-area New England-New York system.
No takes yet. Share an insight, caveat, or question.
Mahapatra et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: