His bundle pacing achieved greater QRS narrowing compared with left bundle branch area pacing (121.2 vs 132.7 ms, p=0.012) in patients with basal LBBB undergoing conduction system pacing.
Cohort (n=75)
Does conduction system pacing (HBP or LBBAP) improve electrical synchrony and QRS duration in patients with left bundle branch block?
Conduction system pacing effectively corrects LBBB and improves electrical synchrony, with His bundle pacing providing greater QRS narrowing than left bundle branch area pacing.
Absolute Event Rate: 121.2% vs 132.7%
p-value: p=0.012
Abstract Background His Bundle Pacing (HBP) and Left Bundle Branch Area Pacing (LBBAP) are emerging alternatives to conventional cardiac resynchronization therapy (CRT) in patients with left bundle branch block (LBBB). However, conduction systema pacing (CSP) does not achieve complete correction in all cases. Ultra-high-frequency ECG (UHF-ECG) is a novel tool currently under investigation for its ability to provide real-time assessment of electrical synchrony and potentially enhance CRT optimization. Objective To assess the feasibility and efficacy of CSP in correcting LBBB, and to compare baseline and post-implantation electrical synchrony using 14-lead UHF-ECG. Methods Patients with basal LBBB referred for device implantation between October 2023 and April 2025 were included. HBP was the first-line pacing strategy, LBBAP the second-line and conventional coronary sinus CRT the third-line. Electrical dyssynchrony was quantified with UHF-ECG as the maximal time difference between the centers of mass of the UHF-QRS complexes in leads V1-V6 and V1-V8 (DYS16 and DYS18). QRS duration (QRSd) was automatically determined by UHF-ECG, distinguishing between total QRSd from the spike (QRSdt) and only pure QRS (QRSdp). Results 75 patients underwent device implantation. CSP successfully corrected LBBB in 68 (90.1%), who were included in the analysis (54.4% male, mean age 73.4 ± 10.4 years, 47.1% HBP and 45.6% LBBAP). Main indications for implantation included new-onset LBBB post-transaortic valve implantation (TAVI) (23.5%), LBBB-induced cardiomyopathy (20.6%) and ischemic cardiomyopathy (19.1%). Mean basal left ventricular ejection fraction (LVEF) was 46.3 ± 13.8%. Among patients with LVEF 40%, CSP significatively improved LVEF (30.4 ± 6.7 vs 38.5 ± 12.7, p0.001). QRSd, area and dyssynchrony were significantly reduced after CSP (p0.001). Comparisons between basal LBBB, CSP, HBP and LBBAP are shown in Figure 1, with no significative differences in electrical synchrony between both CSP techniques, although HBP achieved a greater QRS narrowing compared with LBBAP (121.2 ± 13ms vs 132.7 ± 21ms, p=0.012). At 24-hour follow-up, HBP thresholds improved significantly (p = 0.041) and remained stable in both CSP modalities at 4 2–6 and 13 12–17 months.. HBP R-wave sensing showed non-clinical improvement over time (p=0.002). Picture 2 summarizes comparisons between both CSP techniques, showing no clinically relevant differences in R-wave sensing and capture thresholds. Conclusions CSP is a highly effective strategy for correcting LBBB, achieving significant reductions in QRSd, area, and electrical dyssynchrony as assessed by UHF-ECG. HBP provided greater QRS narrowing, while LBBAP offered lower thresholds during follow-up, which remained stable in both CSP techniques, representing promising alternatives to conventional CRT.Electrical parameters and synchronyMain lead parameters
Ruiz et al. (Mon,) conducted a cohort in Left bundle branch block (LBBB) (n=75). His Bundle Pacing (HBP) vs. Left Bundle Branch Area Pacing (LBBAP) was evaluated on Post-pacing QRS duration (p=0.012). His bundle pacing achieved greater QRS narrowing compared with left bundle branch area pacing (121.2 vs 132.7 ms, p=0.012) in patients with basal LBBB undergoing conduction system pacing.