Why the study?
Direct head-to-head comparisons across pulsed-field ablation platforms with distinct catheter architectures and pulse deliveries remain limited.
Does the choice of pulsed-field ablation catheter architecture (VLCC, pentaspline, or balloon-in-basket) affect procedural metrics and mid-term efficacy in patients undergoing atrial fibrillation ablation?
Does the choice of pulsed-field ablation catheter architecture (VLCC, pentaspline, or balloon-in-basket) affect procedural metrics and mid-term efficacy in patients undergoing atrial fibrillation ablation?
Different pulsed-field ablation catheter architectures yield distinct procedural profiles but broadly comparable acute and mid-term effectiveness for atrial fibrillation ablation.
Introduction Pulsed-field ablation (PFA) is comparable in safety, feasibility, and efficacy to thermal energy for atrial fibrillation (AF). Three platforms embody distinct architectures and pulse deliveries. VARIPULSE (Biosense Webster) is a variable-loop circular catheter (VLCC) delivering bipolar microsecond pulses (3x1.8 kV) across ten ring electrodes; loop diameter adapts to pulmonary vein (PV) size. FARAWAVE (Boston Scientific) is a pentaspline multielectrode catheter (four electrodes per spline) applying biphasic microsecond pulse trains (1.8-2.0 kV per 2.5s) in basket/flower pose with rotational stacking for antral coverage. VOLT (Abbott) is a single-use balloon-in-basket catheter whose eight nitinol splines serve for mapping, pacing, and PFA delivery (1.345-1.7 kV). All three catheter use impedance-based proximity for contact visualization ad magnetic-sensor electroanatomic mapping (EAM) integration. Direct head-to-head comparisons remain limited. PURPOUSE: To compare feasibility, safety and efficacy across VLCC, Pentaspline and Balloon catheter. Methods We analysed consecutive AF ablations using VLCC (n=121), Pentaspline (n=115) or Balloon (n=40). End points: procedure, fluoroscopy and left-atrial (LA) times, number of PFA applications (per-vein/overall), first-pass isolation (FPI), intra-procedural AF termination, and acute safety. Mid-term efficacy (≥6-month) was assessed as AF-free survival. Results Baseline features were broadly balanced (table 1), but persistent AF was more frequent in Pentaspline cohort than in the VLCC and balloon (p<0.05). VLCC had the shortest fluoroscopy and procedural time; the balloon catheter had the shortest LA dwell time (p<0.05). Applications per PV were highest with VLCC (15/vein), intermediate with pentaspline (8), and lowest with Balloon (4); yielding overall deliveries of 54 [33–66], 53.7±10.6, and 14.5 [9.5–17.75] respectively. First pass isolation (FPI): VLCC 87%, Pentaspline 94%, Balloon 87.5% (p<0.05). In patient with ≥ 6 month follow-up, AF free survival did not differ (p=0.988): VLCC 91.3%, Pentaspline 81.8%, Balloon 81.3%. One major complication (transient ST-segment elevation) occurred with the balloon catheter resolved after nitrates infusion. Conclusions Catheter architecture and pulse-delivery strategy translated into distinct procedural profiles with broadly comparable acute and mid-term effectiveness. The balloon-in-basket system required the fewest applications and had the shortest LA dwell time, consistent with a single-shot workflow. The pentaspline system combined high FPI with more frequent intra-procedural AF termination but longer times, reflecting a higher prevalence of persistent AF and PVI+ strategies. The VLCC also achieved high FPI but required more applications, consistent with integrated-mapping, multipoint ring-electrode approach. Safety was favourable across systems, with only one transient coronary event reported.
No takes yet. Share an insight, caveat, or question.
Angelo et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: