Why the study?
ECG-asynchronous pulsed field ablation pulses coinciding with the T wave may theoretically provoke proarrhythmic effects, but clinical evidence regarding its safety remains limited.
Does ECG-asynchronous pulsed-field pulmonary vein isolation increase the risk of ventricular arrhythmias or myocardial injury compared to ECG-synchronous delivery in patients with atrial fibrillation?
Does ECG-asynchronous pulsed-field pulmonary vein isolation increase the risk of ventricular arrhythmias or myocardial injury compared to ECG-synchronous delivery in patients with atrial fibrillation?
ECG-asynchronous pulsed-field ablation for pulmonary vein isolation appears safe and feasible, with no evidence of arrhythmogenesis or excess myocardial injury even when pulses coincide with the T wave.
Answers are grounded in this paper and cite their sources.
No VA events with T-wave exposure supports cautious asynchronous PFA use; leaves open randomized confirmation of safety and synchronization benefit.
Background/Introduction Pulsed field ablation (PFA) catheters, including the PulseSelect™ catheter (Medtronic, MN), employ biphasic pulses, which markedly reduce the risk of ventricular arrhythmias (VA) compared with monophasic waveforms. To further enhance safety, PulseSelect™ enables R-wave synchronization, but also allows pulse delivery in Electrocardiogram (ECG)-asynchronous mode. ECG-asynchronous pulses coinciding with the T wave may theoretically provoke proarrhythmic effects, yet clinical evidence on the safety of ECG-asynchronous PFA remains limited. Purpose To evaluate the procedural safety of ECG-asynchronous pulmonary vein isolation (PVI) using the PulseSelect™ catheter, focusing on the incidence of VA and myocardial injury assessed by serum biomarkers, and to determine whether pulse delivery during the T-wave period is associated with adverse events. Methods We retrospectively analyzed 35 consecutive patients (mean age 67 ± 9 years; 77% male; 63% paroxysmal atrial fibrillation (AF)) who underwent first-time PVI with PulseSelect™ at Hirosaki University Hospital between June and December 2024. ECG-asynchronous pulses were defined as those delivered without R-wave synchronization. Serum biomarkers (troponin T, CPK, CPK-MB, LDH, haptoglobin, NT-proBNP) were measured before and after ablation. The absence of VA or biochemical evidence of myocardial injury attributable to asynchronous pulse delivery were compared between the ECG-synchronous and ECG-asynchronous groups. Procedure time, AF recurrence, and complications were similarly evaluated. Results All procedures were completed without complications. Among 5,940 pulse trains delivered, 2,316 (39%) were ECG-asynchronous, and 745 (32% of ECG-asynchronous) overlapped the T wave. No ventricular tachyarrhythmias or hemodynamic instability occurred during or after T-wave exposure. Biomarker changes did not differ significantly between two groups, and no correlation was observed between T-wave exposure and biomarker elevation. Left atrial dwell time was similar between ECG-asynchronous (41 ± 10 min) and ECG-synchronous groups (45 ± 16 min), indicating no procedural advantage from omitting ECG-synchronization. No complications were observed, and AF recurrence was observed in 4 cases (11%, 3 in the ECG-asynchronous group and 1 in the ECG-synchronous group, p=0.17) during the follow-up period (336 ± 71 days). Conclusions ECG-asynchronous PVI using the PulseSelect™ catheter was feasible and safe, with no evidence of arrhythmogenesis or myocardial injury even when pulses coincided with the T wave. The biphasic waveform appears to provide a safety margin during repolarization. While R-wave synchronization remains recommended, asynchronous delivery may be safely tolerated when synchronization is not achievable.
No takes yet. Share an insight, caveat, or question.
Toyama et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: