Why the study?
Repeat pulmonary vein isolation is commonly performed for recurrent atrial fibrillation, but the optimal radiofrequency energy delivery strategy for reisolation has not been established.
Does high-power short-duration radiofrequency ablation improve 12-month arrhythmia-free survival compared to low-power long-duration ablation in patients undergoing redo pulmonary vein isolation for atrial fibrillation?
Does high-power short-duration radiofrequency ablation improve 12-month arrhythmia-free survival compared to low-power long-duration ablation in patients undergoing redo pulmonary vein isolation for atrial fibrillation?
High-power short-duration ablation demonstrates comparable procedural efficiency and 12-month clinical efficacy to low-power long-duration ablation in repeat pulmonary vein isolation procedures.
Answers are grounded in this paper and cite their sources.
No significant difference observed; hypothesis-generating and should not yet change ablation practice.
Background Repeat pulmonary vein isolation (PVI) is commonly performed to improve outcomes in patients with atrial fibrillation (AF). Although pulmonary vein reconnection remains a major cause of recurrence, the optimal energy delivery strategy for reisolation has not been clearly established. Methods We prospectively evaluated redo PVI procedures performed using point-by-point radiofrequency ablation. Patients underwent either ablation index-guided low-power long-duration (LPLD; 25–35 W) or high-power short-duration (HPSD; 50/90 W) ablation. Procedural parameters, periprocedural complications, and 12-month arrhythmia-free survival were compared. Multivariate logistic regression was used to identify independent predictors of arrhythmia recurrence. Results A total of 170 redo PVI procedures were analysed (LPLD, n = 46; HPSD, n = 124). Total procedure time (130.3 ± 9.3 vs 139.3 ± 6.9 min, p = 0.16), ablation time (96.7 ± 8.5 vs 100.0 ± 6.3 min, p = 0.57), fluoroscopy time (7.1 ± 2.0 vs 7.3 ± 0.9 min, p = 0.85), and radiation dose (575.9 ± 182.8 vs 394.0 ± 110.9 cGy·cm², p = 0.09) were similar between groups. Organised post-PVI atrial tachycardia occurred in 28.3% and 24.2% of patients, respectively (p = 0.59). No major complications occurred in the LPLD group, while one case of cardiac tamponade was reported in the HPSD group (p = 0.22). At 12 months, arrhythmia-free survival was 73.9% in the LPLD group and 81.5% in the HPSD group (p = 0.28). Larger left atrial diameter (per 5 mm; OR 1.61, 95% CI 1.20–2.20, p = 0.0019) and older age (per 10 years; OR 1.76, 95% CI 1.14–2.88, p = 0.016) independently predicted arrhythmia recurrence. Conclusions In repeat PVI procedures, HPSD ablation demonstrated comparable procedural efficiency and clinical efficacy to LPLD ablation. Larger left atrial diameter and older age were independent predictors of arrhythmia recurrence after redo PVI.
No takes yet. Share an insight, caveat, or question.
Kassa et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: