Key result
Balloon-in-basket PFA shows greater troponin T release but less inflammatory activation than cryoballoon ablation.
Why the study?
Both cryoballoon ablation and balloon-in-basket pulsed field ablation may trigger systemic inflammation and myocardial injury, but direct comparisons are lacking.
Does balloon-in-basket pulsed field ablation compared to cryoballoon ablation alter inflammatory and myocardial biomarker responses in patients undergoing pulmonary vein isolation for atrial fibrillation?
Cohort (n=100)
No
Does balloon-in-basket pulsed field ablation compared to cryoballoon ablation alter inflammatory and myocardial biomarker responses in patients undergoing pulmonary vein isolation for atrial fibrillation?
Cryoballoon ablation provokes stronger systemic inflammatory activation, while balloon-in-basket pulsed field ablation causes greater myocardial biomarker release following pulmonary vein isolation.
Background Cryoballoon ablation (CB) is a well-established thermal technique for pulmonary vein isolation (PVI), while balloon-in-basket pulsed field ablation (BiB-PFA) represents a novel non-thermal alternative. Both single-shot systems may trigger systemic inflammation and myocardial injury, yet direct comparisons are lacking. This study aimed to compare inflammatory and myocardial biomarker responses following first-time PVI using CB or BiB-PFA. Methods In this prospective, single-center study, 100 patients undergoing PVI for symptomatic paroxysmal or persistent atrial fibrillation (AF) were enrolled (CB: n = 50; BiB-PFA: n = 50). Venous blood samples were collected before and on the morning after ablation to assess leukocytes, C-reactive protein (CRP), platelets, troponin T, creatine kinase (CK), myoglobin, creatinine, and estimated glomerular filtration rate. Baseline characteristics, procedural data, and acute success were analyzed. Results Patients in the CB group were older (74 vs. 65 years; p = 0.01) and had higher CHA2DS2-VA score (3.0 vs. 2.0; p = 0.009). Acute PVI was achieved in all cases CB was associated with greater increases in leukocytes (Δ2.5 vs. 1.1 × 109/L; p = 0.05) and CRP (Δ5.8 vs. 3.4 mg/L; p = 0.02), whereas BiB-PFA showed higher rises in CK (Δ217 vs. 103 U/L; p = 0.01) and troponin T (Δ1129 vs. 614.5 ng/L; p = 0.01). (Figure 1) No significant correlation was found between energy delivery and biomarker changes. Conclusion CB and BiB-PFA elicit distinct systemic responses. CB provoked stronger inflammatory activation, while BiB-PFA caused greater myocardial biomarker release, suggesting energy- and device-specific effects
No takes yet. Share an insight, caveat, or question.
Hatahet et al. (2026) conducted a cohort in Symptomatic paroxysmal or persistent atrial fibrillation (n=100). Balloon-in-basket pulsed field ablation (BiB-PFA) vs. Cryoballoon ablation (CB) was evaluated on Inflammatory and myocardial biomarker responses (leukocytes, CRP, troponin T, CK). Balloon-in-basket pulsed field ablation caused greater troponin T release (Δ1129 vs 614.5 ng/L; p=0.01) than cryoballoon ablation, which provoked stronger inflammatory activation (CRP and leukocytes).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: