Why the study?
Optimal management of pacing-induced cardiomyopathy remains debated, and comparative data on upgrading to BiVP versus LBBaP are limited.
Does upgrading to left bundle branch area pacing compared to biventricular pacing improve functional status and ventricular function in patients with pacing-induced cardiomyopathy?
Does upgrading to left bundle branch area pacing compared to biventricular pacing improve functional status and ventricular function in patients with pacing-induced cardiomyopathy?
Answers are grounded in this paper and cite their sources.
Upgrading to either biventricular pacing or left bundle branch area pacing provides comparable short-term improvements in ventricular function and electrical synchrony for patients with pacing-induced cardiomyopathy.
Background Pacing-induced cardiomyopathy (PiCM) is a recognized complication of chronic right ventricular (RV) pacing, yet optimal management remains debated. Upgrading to biventricular pacing (BiVP) or left bundle branch area pacing (LBBaP) may reverse dysfunction, but comparative data are limited. Objective To compare the efficacy and safety of upgrading to BiVP versus LBBaP in patients with PiCM. Methods In this single-center retrospective cohort, 31 patients with symptomatic PiCM underwent upgrade to BiVP (n=16) or LBBaP (n=15) between 2014 and 2024. PiCM was defined as a >10% absolute LVEF decline to <50% with RV pacing >20%. Clinical (NYHA class), electrocardiographic (paced QRS duration), and echocardiographic (LVEF, LVEDD) parameters were assessed before and after upgrade. ROC analysis evaluated paced QRS reduction for predicting LVEF normalization. Results Median follow-up was 10.0 months. Both groups showed significant NYHA class improvement, QRS narrowing, and LVEF increase (BiVP: +8.44%, LBBaP: +6.60%; p=0.859 between groups). No significant intergroup differences were observed for any clinical or echocardiographic outcomes. A paced QRS reduction ≥41 ms predicted LVEF ≥50% with 80% sensitivity and 81% specificity (AUC=0.876, p=0.001). No major device-related complications occurred. Conclusions BiVP and LBBaP upgrades yield comparable short-term improvements in functional status, ventricular function, and electrical synchrony in PiCM. Paced QRS reduction may serve as a helpful marker of recovery. Larger, prospective studies are warranted to confirm these findings.
No takes yet. Share an insight, caveat, or question.
Dogan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: