Key result
RF ablation shows no difference in AF recurrence versus cryoballoon ablation in HCM.
Why the study?
The optimal catheter ablation modality and long-term efficacy for AF in HCM patients remain uncertain, particularly among Japanese patients.
Does radiofrequency ablation reduce AF recurrence compared to cryoballoon ablation in Japanese patients with hypertrophic cardiomyopathy undergoing first-time catheter ablation?
Cohort (n=43)
No
Does radiofrequency ablation reduce AF recurrence compared to cryoballoon ablation in Japanese patients with hypertrophic cardiomyopathy undergoing first-time catheter ablation?
Answers are grounded in this paper and cite their sources.
In patients with hypertrophic cardiomyopathy undergoing first-time AF ablation, there was no significant difference in recurrence between radiofrequency and cryoballoon ablation, though non-pulmonary vein mechanisms frequently contributed to recurrence.
Background/Introduction Atrial fibrillation (AF) is a frequent arrhythmic complication in patients with hypertrophic cardiomyopathy (HCM) and is associated with increased morbidity and mortality. Catheter ablation (CA) has emerged as an important rhythm control strategy; however, the optimal ablation modality and its long-term efficacy in HCM remain uncertain, particularly among Japanese patients. Purpose This study aimed to evaluate the procedural and clinical outcomes of first-time CA for AF in HCM patients, comparing radiofrequency (RF) ablation with cryoballoon (CB) ablation. Methods We retrospectively analyzed 43 consecutive HCM patients who underwent first-time CA for AF between 2016 and 2024 at a single tertiary center. HCM was diagnosed according to the JCS 2018 Guideline on Diagnosis and Treatment of Cardiomyopathies. Patients were divided into two groups according to the energy source: RF (n=26) and CB (n=17). Pulmonary vein isolation (PVI) was the primary lesion set, and additional ablation beyond PVI was performed at the operator’s discretion. AF recurrence was defined as any atrial tachyarrhythmia lasting ≥30 seconds beyond a 3-month blanking period. Procedural outcomes, recurrence mechanisms, and PV reconnection findings at redo ablation were compared between the two groups. Results The mean age was 63±10 years, and 70% were male. Paroxysmal AF was present in 67% and persistent AF in 33%. Baseline clinical characteristics were comparable between groups. Acute PVI success was achieved in all patients. During a median follow-up of 24 months, AF/AT recurrence occurred in 14 patients (RF 53.8% vs. CB 35.3%, p=0.349). Redo ablation was performed in 11 patients (RF 8, CB 3). PV reconnection was identified in 12/32 (37.5%) PVs in the RF group and 2/12 (16.7%) in the CB group (p=0.282). Non-PV mechanisms, including the left atrial posterior wall or mitral isthmus conduction, accounted for 6 of 11 recurrence cases. No major periprocedural complications, including stroke or cardiac tamponade, were observed. Conclusion In Japanese patients with HCM undergoing first-time AF ablation, recurrence tended to be more frequent after RF ablation than after CB ablation, although the difference was not statistically significant. Non-PV mechanisms contributed to more than half of recurrence cases, suggesting that tailored substrate modification beyond standard PVI may be necessary to achieve durable rhythm control in this population.
No takes yet. Share an insight, caveat, or question.
Inamura et al. (2026) conducted a cohort in Atrial fibrillation in hypertrophic cardiomyopathy (n=43). Radiofrequency (RF) ablation vs. Cryoballoon (CB) ablation was evaluated on AF/AT recurrence (any atrial tachyarrhythmia lasting ≥30 seconds beyond a 3-month blanking period) (p=0.349). Radiofrequency ablation for atrial fibrillation in hypertrophic cardiomyopathy resulted in a 53.8% recurrence rate compared to 35.3% with cryoballoon ablation.
Synapse has enriched 10 related papers. Consider them for comparative context: