Why the study?
CIED infection is a major cause of morbidity, rehospitalization, and healthcare burden, making the identification of clinical and procedural predictors essential to guide prevention strategies in high-risk recipients.
What are the independent predictors of CIED-related infection in patients undergoing ICD or CRT-D procedures?
What are the independent predictors of CIED-related infection in patients undergoing ICD or CRT-D procedures?
Procedural complexity, specifically CRT-D implantation and longer procedure duration, are the strongest independent predictors of CIED infection, emphasizing the need for procedural optimization.
Answers are grounded in this paper and cite their sources.
CRT-D and longer procedures linked to higher CIED infection risk; hypothesis-generating for optimization strategies pending prospective trials.
Introduction Cardiac implantable electronic device (CIED) infection remains a major cause of morbidity, rehospitalization, and healthcare burden. Identifying clinical and procedural predictors of infection is essential to guide prevention strategies in high-risk recipients. Methods We retrospectively analyzed 1,699 consecutive patients who underwent ICD or CRT-D implantation, replacement, or revision between 2017 and 2024. Among them, 1,211 (71%) received no envelope, 241 (14%) Tirex, and 247 (15%) Tauropace. Baseline clinical and procedural characteristics, comorbidities, and medical therapy were collected. Independent predictors of CIED-related infection were identified using multivariable logistic regression including demographic, procedural, and clinical variables. Results The mean age was 71 ± 11 years, 75% were male, and 22% underwent CRT-D implantation. Diabetes and chronic kidney disease were present in 56% and 47% of patients, respectively. Overall, infection occurred in 29 patients (1.7%). Compared with non-infected patients, those with infection more frequently received a CRT-D system and had longer procedures. At multivariable analysis, CRT-D device (OR 4.00, 95% CI 1.31–12.28, p = 0.015) and procedure duration (OR 1.02 per minute, 95% CI 1.01–1.04, p = 0.008) were independent predictors of infection. Age, sex, ejection fraction, diabetes, renal dysfunction, and antithrombotic therapy were not significantly associated with infection risk. Conclusions In this large real-world cohort of high-risk CIED recipients, procedural complexity—specifically CRT-D implantation and longer implant duration—emerged as the strongest independent predictors of infection. These findings highlight the central role of procedural optimization and meticulous aseptic technique to minimize CIED-related infections, regardless of envelope use.
No takes yet. Share an insight, caveat, or question.
Cocchiara et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: