Case report shows successful extraction of a trapped Proglide device during PCI, suggesting endovascular solutions for complications.
Vascular closure devices (VCD) are commonly used for rapid haemostasis after femoral arterial cannulation, however, serious adverse events may rarely occur. We describe a case where use of Perclose Proglide for closure of the right femoral artery (RFA) access site led to focal arterial dissection, entrapping the footplate of a second Proglide device during staged percutaneous coronary intervention (PCI). The trapped device was eventually extracted using intravascular ultrasound (IVUS)-guided balloon angioplasty with cross-over approach. This case highlights the potential complications of VCD and possible endovascular strategies in tackling such issues.
No takes yet. Share an insight, caveat, or question.
Lai et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: