Answers are grounded in this paper and cite their sources.
Recently, we have proposed the concept of a crystalline joint by melted bulk (CJMB) for making a superconducting connection between GdBa 2 Cu 3 O 7-δ (Gd123)-coated conductors (wire) using a wire-bulk-wire structure. In a model experiment, a joint between a Gd123-coated conductor and large piece of Y123 bulk (wire-bulk) as one-half of a joint was demonstrated, resulting in a superconducting joint with a critical current of 10 A at 77 K, and a high tensile strength greater than 100 MPa. In this study, a joint between coated conductors in a wire-bulk-wire structure was constructed using a Yb123 sheet fabricated from bulk material. As a result of using the CJMB method, we successfully fabricated a superconducting joint over the short time of less than 1 day (including joint formation and oxygen annealing). A persistent current coil having a superconducting joint was fabricated using the CJMB method. Its resistance was estimated from the current decay rate of the coil, to have a low value not exceeding 10 -10 Ω after one day following the external power cutoff.
No takes yet. Share an insight, caveat, or question.
Jin et al. (2018) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: