Key result
Endoluminal stent-grafting successfully sealed the primary entry tear in 100% (9/9) of patients with acute type B aortic dissection, with no severe intraoperative complications.
Why the study?
Does endoluminal stent-graft placement improve aortic remodeling and safely seal the primary entry tear in patients with acute type B aortic dissection?
Observational (n=9)
Does endoluminal stent-graft placement improve aortic remodeling and safely seal the primary entry tear in patients with acute type B aortic dissection?
Endoluminal stent-grafting is a feasible and effective method for sealing the primary entry tear and promoting favorable aortic remodeling in acute type B aortic dissection.
Answers are grounded in this paper and cite their sources.
Stent-grafting feasible in small acute type B series; leaves open efficacy, durability, and need for randomized trials.
OBJECTIVES: This study was performed to evaluate the feasibility, safety and effectiveness of endovascular stent-grafting in treating Stanford type B acute aortic dissection. We describe our first clinical experiences and initial results with stent-grafting across the primary entry tear in patients with acute aortic dissection type B. METHODS: Between March 2000 and August 2001, nine patients with acute type B dissection were treated endoluminally by stent-graft implantation. There were seven male and two female patients with a mean age of 63 years (between 48 and 85 years). In all nine patients aortic dissection was diagnosed by multislice computed tomography (CT) angiography. All nine patients had a maximal aortic diameter of 5.5 cm or more and recurrent pain, one patient showed hemoptysis. This patient with signs of a contained rupture was treated under emergency condition, the eight remaining patients were in hemodynamic stabile condition at the time of intervention. The GORE Excluder stent-graft system was used in eight patients (mean 1.8 stents/patient) and the TALENT stent-graft system in one patient, which were introduced transfemorally. RESULTS: The primary entry tear could be sealed successfully in all nine patients. Complete thrombosis of the false thoracic aortic lumen was obtained in two patients, in the remaining seven patients the false lumen was obliterated in the area of the thoracic aorta but perfused via re-entries in the abdominal region. No severe intraoperative complications occurred. One patient developed bilateral incomplete paraplegia with motor and sensory deficits affecting completely the right leg and partially the left leg, 14 h after intervention. A cerebrospinal fluid drainage was initiated by inserting a lumbar catheter. All nine patients, including the patient with the transient paraplegia, could be discharged from the hospital in excellent condition and without remaining neurologic deficits. Control CT scans showed a reduction of the false lumen from 2.34+/-0.58 to 0.7+/-0.44 cm and an increase of the true lumen from 1.56+/-0.5 to 4.10+/-0.6 cm in the thoracic aortic region. Mean ICU stay was 1.8 days, mean postoperative hospital stay was 7.6 days. CONCLUSIONS: Stent-grafting of acute type B dissections may represent a very effective and promising new method by closure of the primary entry tear, thereby minimizing the risk of rupture of the thoracic aorta and optimizing distal perfusion by decompression of the true lumen.
No takes yet. Share an insight, caveat, or question.
Hutschala et al. (2002) conducted an observational in Acute aortic dissection type B (n=9). Endoluminal stent-graft placement was evaluated on Sealing of the primary entry tear. Endoluminal stent-grafting successfully sealed the primary entry tear in 100% (9/9) of patients with acute type B aortic dissection, with no severe intraoperative complications.
Synapse has enriched 10 related papers. Consider them for comparative context: