Key result
Eliminating routine pre-discharge echocardiography after TAVR was associated with a similar incidence of 30-day composite adverse events compared to routine imaging.
Why the study?
Post-procedural, pre-discharge TTE assists in assessing prosthesis function and paravalvular leak after TAVR, but the safety of eliminating routine pre-discharge TTE on 30-day outcomes was unknown.
Does eliminating routine pre-discharge transthoracic echocardiogram affect 30-day safety outcomes in patients undergoing TAVR?
Cohort (n=330)
No
Does eliminating routine pre-discharge transthoracic echocardiogram affect 30-day safety outcomes in patients undergoing TAVR?
Eliminating routine pre-discharge transthoracic echocardiogram after TAVR is safe and associated with comparable 30-day outcomes, which may improve cost-efficiency and healthcare utilization.
Answers are grounded in this paper and cite their sources.
Should not yet change TAVR discharge protocols; leaves open need for randomized confirmation of safety.
OBJECTIVES: The aim of this study was to determine the safety of eliminating the pre-discharge transthoracic echocardiogram (TTE) on 30-day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TTE is utilized before, during, and after TAVR. Post-procedural, pre-discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR. METHODS: Patients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre-discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post-TAVR. RESULTS: A total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre-discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre-discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre-discharge TTE group and none in the group without pre-discharge TTE at 30-day follow-up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre-discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71). CONCLUSIONS: Elimination of the pre-discharge TTE is safe and associated with comparable 30-day outcomes to routine pre-discharge TTE. These findings have implication for TAVR practice cost-efficiency and health care utilization.
No takes yet. Share an insight, caveat, or question.
Welle et al. (2021) conducted a cohort in Transcatheter aortic valve replacement (TAVR) (n=330). Elimination of pre-discharge transthoracic echocardiogram (TTE) vs. Routine pre-discharge TTE was evaluated on Total composite primary and secondary adverse events at 30 days (p=0.56). Eliminating routine pre-discharge echocardiography after TAVR was associated with a similar incidence of 30-day composite adverse events compared to routine imaging.
Synapse has enriched 10 related papers. Consider them for comparative context: