Answers are grounded in this paper and cite their sources.
Investigates heparinized grafts improving vascular compatibility and function, indicating promise for clinical use.
The clinical success of vascular grafts relies on three main prerequisites: artery-tuned mechanics, a cell-supportive microstructure, and a thromboresistant interface. Most current solutions address only a subset of this triad and equate mechanical matching with compliance alone, which can lead to disturbed hemodynamics, maladaptive mechanobiology, and adverse graft-host biochemical interactions that frequently culminate in clinical complications and graft failure. This study presents polyurethane-based heparin-functionalized elastomeric nanofibrillar grafts (H-ENGs) that integrate all three prerequisites while allowing multi-parameter mechanical mimicry. To address the principal failure mode of early thrombosis, a small fraction of polyethyleneimine (PEI) is added to the ENG electrospinning solution to form P-ENGs, enabling one-step covalent heparin conjugation to form H-ENGs. The decoupled design of the ENG platform preserves the biomimetic microstructure and mechanics following PEI incorporation and heparinization, enabling adaptable, indication-specific optimization. In vitro, H-ENGs demonstrate strong benchtop performance, exhibiting a suture retention strength of 2.91 ± 0.40 N and a burst pressure of 634 ± 66 mmHg, both above physiological requirements. Relative to non-heparinized ENG controls, H-ENGs reduce the water contact angle from 117.3° to 90.6°, platelet adhesion density from 410 ± 61 to 35 ± 9 platelets/mm 2, and static blood clot formation from 1.2 ± 0.4 to 0.3 ± 0.8 mg/cm 2, consistent with markedly improved hemocompatibility. Pilot porcine abdominal aorta interposition studies ( n = 2) confirm surgical feasibility, immediate anastomotic hemostasis, and absence of suture-hole bleeding. At two weeks, H-ENGs remain patent, show no aneurysmal degeneration, and retain artery-like pulsatility (1.99 ± 1.41% vs 1.72 ± 1.82%). Ex vivo mechanical analysis confirms preservation of biomimetic mechanics, while XPS shows persistence of the S 2p signal, indicating heparin stability under high-flow conditions. Collectively, these findings suggest that H-ENGs satisfy the three core requirements for clinically successful vascular grafts and warrant further evaluation in more extensive preclinical studies.
No takes yet. Share an insight, caveat, or question.
Zermeno et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: