Key result
Transcatheter valve-in-valve implantation cuts peak gradient ~85% in chronic type A dissection.
Why the study?
Management of severe aortic stenosis due to premature prosthesis degeneration in patients with concomitant chronic type A aortic dissection presents a clinical challenge requiring innovative procedural approaches.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
Transcatheter aortic valve-in-valve implantation can be safely and successfully performed in patients with severe bioprosthetic aortic stenosis and concomitant chronic type A aortic dissection using careful navigation and 3D CT-fluoroscopy fusion imaging.
A 74-year old lady presented to our outpatient clinic with dyspnoea on exertion and fatigue after surgical aortic valve replacement with a 21 mm Medtronic Hancock II prosthesis in 2013. Transthoracic echocardiography showed premature prosthesis degeneration with severe aortic stenosis (peak pressure gradient (PG) 79 mmHg, mean pressure gradient (MPG) 48 mmHg; Figure A) due to immobilization of 2 leaflets (former right coronary and non-coronary cusps, Supplementary material online, Video S 1), so that a screening for transcatheter valve-in-valve implantation was initiated. An electrocardiogram (ECG)-gated, multi-slice high-resolution computed tomography (CT) scan revealed a chronic dissection of the ascending aorta (Stanford type A dissection, Figure B) as a random finding most likely associated with the previous heart surgery for aortic valve replacement. Since a polytetrafluoroethylene coating of the ascending aorta was performed previously and due to the circumscribed, chronic dissection, the heart team decision recommended a transcatheter aortic valve implantation as a valve-in-valve procedure. In this particular patient, an Evolut R 23 mm prosthesis was preferred for two considerations: (i) the supra-annular design will yield lower residual gradients in this small anatomy (Hancock II 21 mm prosthesis with a true inner diameter of 16.5 mm) and (ii) the flexible, small-sized (14F) delivery system with a smooth surface that allows to navigate through the dissected ascending aorta with a low risk of mechanical injury. During the procedure, all catheters were advanced with care and guided by real-time 3D CT—fluoroscopy fusion imaging (HeartNavigator 3.0). Proper position of all catheters in the true lumen was confirmed by repeated contrast injections (Figure C). In order to facilitate navigating through the ascending aorta with the valve delivery system, a pigtail catheter with a Lunderquist guidewire inside was placed in the bulbus aortae (non-coronary cusp) and kept under gentle forward push (Figure D). This manoeuver aimed to move the dissection membrane to the outer curve of the aorta, so that the risk of an interaction with the chronic dissection or even a propagation of the latter by the valve delivery system was kept to a minimum. 3D CT—fluoroscopy fusion imaging helped to identify the true lumen at the inner curve of the ascending aorta while advancing the catheter (Figure E; Supplementary material online, Video S 2). After one recapture manoeuver due to a too ventricular position, the Evolut R prosthesis was deployed in an optimal valve position (Supplementary material online, Video s S 3 and S 4). Angiography of the bulbus aortae as well as transoesophageal echocardiography showed no aortic regurgitation (Figure F; Supplementary material online, Video S 5) and invasive recordings documented an excellent haemodynamic result (peak-to-peak gradient down to 9 mmHg from previously 61 mmHg, Figure G). The patient was extubated immediately after the procedure, clinical assessment on the intensive care unit showed no neurological abnormalities. A CT scan on the next day ruled out any significant change or propagation of the chronic type A dissection (Figure H). After rapid recovery, the patient was discharged home on Day 7 after the procedure.
No takes yet. Share an insight, caveat, or question.
Schulz et al. (2017) conducted a case report in Severe aortic stenosis with premature prosthesis degeneration and chronic type A aortic dissection (n=1). Transcatheter aortic valve-in-valve implantation (Evolut R 23 mm) was evaluated on Procedural success and haemodynamic result. Transcatheter aortic valve-in-valve implantation was successfully performed in a patient with a chronic type A aortic dissection, reducing the peak-to-peak gradient from 61 mmHg to 9 mmHg.
Synapse has enriched 10 related papers. Consider them for comparative context: