Key result
Lead V2 R-wave duration over 50 ms predicts sub-pulmonary cusp RVOT-PVCs with perfect specificity.
Why the study?
To evaluate how well surface ECG predicts RVOT-PVC origin and examine the role of ICE during completely fluoroless radiofrequency ablation.
Does surface ECG predict the anatomical origin of RVOT-PVCs in patients undergoing ICE-guided zero-fluoroscopy ablation?
Observational (n=20)
No
Does surface ECG predict the anatomical origin of RVOT-PVCs in patients undergoing ICE-guided zero-fluoroscopy ablation?
Effect estimate: AUC 0.882 (95% CI 0.718-1.000)
p-value: p=0.039
An R-wave duration ≥50 ms in lead V2 accurately predicts a sub-pulmonary cusp origin for RVOT-PVCs, aiding in targeted zero-fluoroscopy ablation using ICE and 3D mapping.
ECG R-wave duration ≥50 ms in V2 may predict sub-pulmonary cusp PVCs; leaves open ICE's role in guiding ablation.
Objective: This study aims to evaluate how well surface electrocardiograms (ECG) predict premature ventricular contraction (PVCs) originating from the right ventricular outflow tract (RVOT) and to examine the role of intracardiac echocardiography (ICE) during their radiofrequency ablation. Methods: From October 2022 to December 2023, we conducted a prospective study at the Second Hospital of Hebei Medical University, enrolling 20 consecutive patients with RVOT-PVCs. In our study, utilizing ICE and the CARTO 3D electroanatomical mapping system, all procedures were performed under a completely fluoroless condition. Ablation sites were categorized into two subgroups: supra-pulmonary cusp (n = 3) and sub-pulmonary cusp (n = 17). Preoperative ECG parameters were systematically analyzed. ICE and CARTO mapping were employed to precisely localize and ablate the PVC foci, with detailed spatial electroanatomical characterization. Results: Of the 20 patients, the origins of PVCs were found in two regions: 17 patients (85%) had PVCs originating from the sub-pulmonary cusp, while 3 patients (15%) had PVCs from the supra-pulmonary cusp. All supra-pulmonary cusp ablation targets were located in the left pulmonary cusp, 3.33 ± 0.33 mm above the cusp base. Sub-pulmonary cusp PVCs were predominantly clustered at the left anterior cusp junction (13/17, 76.5%), with one case (5.9%) at the right anterior cusp junction, averaging 2.53 ± 0.38 mm from the cusp base. Additionally, an R-wave duration ≥50 ms in lead V2 predicted sub-pulmonary cusp localization with 70.6% sensitivity and 100% specificity. Conclusion: ICE can clearly visualize the anatomical structures of the right ventricular outflow tract, which aids in accurately determining the ablation site. In lead V2, an R wave duration of 50 milliseconds or longer exhibits certain predictive value for ventricular premature beats originating below the pulmonary valve sinus. For PVCs originating below the pulmonary valve, the ablation target sites are primarily concentrated at the junction of the left-anterior pulmonary sinus cusp.
No takes yet. Share an insight, caveat, or question.
Cui et al. (2025) conducted an observational in Right ventricular outflow tract premature ventricular contractions (n=20). R-wave duration ≥50 ms in lead V2 vs. R-wave duration <50 ms in lead V2 was evaluated on Prediction of sub-pulmonary cusp localization (AUC 0.882, 95% CI 0.718-1.000, p=0.039). An R-wave duration of 50 ms or greater in lead V2 predicted sub-pulmonary cusp localization of right ventricular outflow tract premature contractions with 70.6% sensitivity and 100% specificity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: