Key result
3D printing-guided PT-Valve achieves ~100% procedural success in severe pulmonary regurgitation with enlarged RVOT.
Why the study?
Severe pulmonary regurgitation frequently occurs after transannular patch repair of tetralogy of Fallot, causing an enlarged native right ventricular outflow tract with varying shapes.
Does 3D printing-guided transcatheter pulmonary valve replacement improve right ventricular remodeling in patients with severe pulmonary regurgitation and enlarged native right ventricular outflow tracts?
Observational (n=8)
No
Does 3D printing-guided transcatheter pulmonary valve replacement improve right ventricular remodeling in patients with severe pulmonary regurgitation and enlarged native right ventricular outflow tracts?
3D printing-guided transcatheter pulmonary valve replacement using a self-expanding valve is safe and effectively reverses right ventricular remodeling in patients with severe pulmonary regurgitation and enlarged native outflow tracts.
Answers are grounded in this paper and cite their sources.
Supports feasibility in enlarged native RVOTs; leaves open confirmation of durability and remodeling benefits in prospective trials.
Background: Severe pulmonary regurgitation (PR) often occurs following a transannular patch repair of tetralogy of Fallot, resulting in an enlarged native right ventricular outflow tract (nRVOT) with varying shapes. Methods: We conducted a single-center study with eight patients having severe PR and enlarged nRVOT (diameters ≥ 29 mm). Transcatheter pulmonary valve replacement (TPVR) was performed using the self-expanding PT-Valve. Preoperative evaluation included echocardiography, computed tomography, and magnetic resonance imaging. A 3D-printed model of the nRVOT was used for preoperative assessment. Follow-up data were collected in 1-year follow-up. Results: PT-Valve was successfully implanted in all patients, resulting in immediate improvement of severe PR. Pulmonary artery diastolic pressure increased significantly (p < 0.001). No deaths or coronary compression occurred during the procedure. Over a 1-year follow-up, no stent displacement or fracture occurred. Only two patients had trace paravalvular leaks. Magnetic resonance imaging revealed a reversal of right ventricular remodeling, with a significant reduction in right ventricular end-diastolic volume index (p < 0.001) and improved right ventricular ejection fraction (p < 0.001). All patients achieved primary endpoints. Conclusion: 3D printing-guided PT-Valve implantation in enlarged nRVOT for severe PR is safe and effective, expanding TPVR indications and offering potential treatment for a broader patient population.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2023) conducted an observational in Severe pulmonary regurgitation with enlarged native right ventricular outflow tract (n=8). 3D printing-guided PT-Valve implantation was evaluated on Successful operation and successful device implantation without need for device removal within 24 hours. Transcatheter pulmonary valve replacement using the 3D printing-guided PT-Valve was successful in 100% of patients with severe pulmonary regurgitation and enlarged right ventricular outflow tracts.
Synapse has enriched 10 related papers. Consider them for comparative context: