Compares dosimetric performance and workflow efficiency of breast radiotherapy techniques in low-resource settings, indicating optimal approaches for large-breasted patients.
Introduction Breast radiotherapy in low-and-middle-income countries (LMICs) must balance target coverage, organ-at-risk (OAR) sparing, and workflow efficiency in resource-limited environments. This is pronounced in large or pendulous breasts treated on flattening-filter-free (FFF) linear accelerators (LINACs), where beam characteristics and larger fields can complicate dose homogeneity. This study compared the dosimetric performance and planning efficiency of breast radiotherapy techniques on a Halcyon platform. Materials and methods Thirty patients with large breast anatomy (separation >25 cm) were replanned using 3D conformal radiotherapy (3DCRT), intensity modulated radiotherapy (IMRT) with two- and four fields (IMRT4F), volumetric modulated arc therapy (VMAT), and VMAT with butterfly fields (VMATBF). Corresponding AutoPTV-based plans, generated from 3DCRT isodose contours, were also evaluated. Plans were generated in Eclipse v15.6 using Anisotropic Analytical Algorithm for delivery on a Halcyon 2.0 LINAC (40.05 Gy in 15 fractions). Target coverage, homogeneity, conformity, near-maximum dose and heart and lung OAR metrics were assessed. Planning efficiency and learning effects were evaluated using recorded planning times. Statistical analysis used one-way ANOVA with Tukey post-hoc testing (p < 0.05). Results Meaningful differences in target coverage and dose homogeneity were observed between techniques (p < 0.05). IMRT4F achieved the highest and most consistent target coverage (median V95% approximately 95% for both cohorts), most closely approaching the V95% ≥ 97% goal, with acceptable hotspot control, while 3DCRT frequently failed to meet coverage criteria. VMAT improved conformity (p < 0.05) but increased low-dose spread and planning time. Planning time was influenced by technique (p < 0.0001) and training (p = 0.0065), with IMRT options showing the greatest improvement (∼53% reduction). AutoPTV produced dosimetric outcomes comparable to manually contoured PTVs (p > 0.05). Conclusion AutoPTV IMRT4F represents a clinically feasible and resource-appropriate approach for large-breasted patients treated on Halcyon systems in LMIC settings, providing robust dosimetric performance with improved workflow efficiency.
No takes yet. Share an insight, caveat, or question.
Groenewald et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: