Systematic review reports responder rates for hypoglossal nerve stimulation in obstructive sleep apnea, indicating clinical benefits and variability.
Background: Hypoglossal nerve stimulation (HNS) is an established surgical therapy for adults with moderate-to-severe obstructive sleep apnea (OSA) who are intolerant to positive airway pressure. Although aggregate response rates of ~70–80% have been reported, substantial variability across clinical settings remains poorly understood. Prior meta-analyses have largely emphasized pooled continuous outcomes, limiting interpretation of responder-based endpoints and drivers of between-study heterogeneity. Methods: A PRISMA-compliant systematic review and meta-analysis was performed. MEDLINE, Embase, and Cochrane CENTRAL were searched from inception through 31 December 2025. Eligible studies enrolled adults with OSA treated with implantable HNS, reported Sher-defined response (≥50% AHI reduction and residual AHI < 20 events/hour), and/or continuous outcomes, and included ≥20 patients. Random-effects models (REML) were applied. Heterogeneity was quantified using I2 and τ2, with prediction intervals. Meta-regression assessed baseline AHI, BMI, and follow-up duration. Subgroup analyses examined device laterality, stimulation modality, sleep assessment method, and follow-up. Results: Thirty-eight studies (39 cohorts; n = 3220) were included. The pooled Sher response rate was 74.0% (95% CI 67.6–79.5%). Heterogeneity was substantial. HNS significantly improved all continuous outcomes (AHI −23.3 events/hour; ESS −4.5 points; ODI −14.5 events/hour). Comparative analyses favored HNS over surgical comparators, inactive stimulation, and delayed treatment. Revision and explantation rates were 5% and 4%, respectively. Meta-regression showed no significant effects of baseline AHI, BMI, or follow-up, explaining negligible variance. Subgroups suggested numerically higher response with breathing-synchronized stimulation, but heterogeneity remained high. Conclusions: HNS achieves Sher response in approximately three-quarters of appropriately selected CPAP-intolerant OSA patients, with durable clinical benefits and a favorable safety profile. Persistent unexplained heterogeneity highlights limitations of conventional predictors and underscores the need for more granular response determinants.
No takes yet. Share an insight, caveat, or question.
Heiser et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: