Examines a protection scheme that improves error reduction in flexible DC transmission lines, suggesting enhanced reliability.
Existing single-ended protection schemes for flexible DC transmission lines are negatively affected by traveling wave (TW) refraction and reflection interference and nonlinear overfitting under low-resistance faults. To address this, in this study, line-mode voltage reverse TWs are mathematically analyzed, revealing that internal faults and forward external faults exhibit single- and double-exponential attenuation, respectively. An adaptive constant-value flattening method is proposed to suppress subsequent TW refraction and reflection. Additionally, a composite fitting strategy utilizing Levenberg–Marquardt (LM) and Moore–Penrose pseudoinverse (PINV) algorithms is proposed to fit the measured waveforms, solving the problem of low-resistance overfitting and amplifying residual differences between internal and external faults. Based on these principles, a novel single-ended protection scheme is proposed. Simulations verify that this scheme exhibits a high operating speed and strong robustness against different fault distances, different fault resistances, and noise.