Key result
The absolute T2 threshold approach (aT2 < 20 ms) significantly underestimated the volume of intramyocardial hemorrhage compared to the subject-specific T2 method in patients with reperfused STEMI.
Why the study?
Despite a lack of consensus studies, two different T2 CMR methods are interchangeably used to quantify intramyocardial hemorrhage, prompting an evaluation of whether they yield equivalent information.
Does the method of T2 CMR quantification (ssT2 vs aT2 < 20 ms) affect the measured T2 and volume of intramyocardial hemorrhage in STEMI patients and animal models?
Observational (n=70)
Yes
Does the method of T2 CMR quantification (ssT2 vs aT2 < 20 ms) affect the measured T2 and volume of intramyocardial hemorrhage in STEMI patients and animal models?
The choice of T2 CMR quantification method (subject-specific vs absolute threshold) significantly influences the measured characteristics of intramyocardial hemorrhage, suggesting a need for standardized approaches.
Absolute T2 thresholding may underestimate IMH volume in reperfused STEMI; leaves open optimal quantification standards for future validation.
Background T2* cardiovascular magnetic resonance (CMR) is commonly used in the diagnosis of intramyocardial hemorrhage (IMH). For quantifying IMH with T2* CMR, despite the lack of consensus studies, two different methods [subject-specific T2* (ssT2*) and absolute T2* thresholding (aT2* < 20 ms)] are interchangeably used. We examined whether these approaches yield equivalent information. Methods ST elevation myocardial infarction (STEMI) patients (n = 70) were prospectively recruited for CMR at 4–7 days post revascularization and for 6-month follow up (n = 43). Canines studies were performed for validation purposes, where animals (n = 20) were subject to reperfused myocardial infarction (MI) and those surviving the MI (n = 16) underwent CMR at 7 days and 8 weeks and then euthanized. Both in patients and animals, T2* of IMH and volume of IMH were determined using ssT2* and aT2* < 20 ms. In animals, ex-vivo T2* CMR and mass spectrometry for iron concentration ([Fe] Hemo ) were determined on excised myocardial sections. T2* values based on ssT2* and absolute T2* threshold approaches were independently regressed against [Fe] Hemo and compared. A range of T2* cut-offs were tested to determine the optimized conditions relative to ssT2*. Results While both approaches showed many similarities, there were also differences. Compared to ssT2*, aT2* < 20 ms showed lower T2* and volume of IMH in patients and animals independent of MI age (all p < 0.005). While T2* determined from both methods were highly correlated against [Fe] Hemo (R 2 = 0.9 for both), the slope of the regression curve for ssT2* was significantly larger as compared to aT2* < 20 ms (0.46 vs. 0.32, p < 0.01). Further, slightly larger absolute T2* cut-offs (patients: 23 ms; animals: 25 ms) showed similar IMH characteristics compared to ssT2*. Conclusion Current quantification methods have excellent capacity to identify IMH, albeit the T2*of IMH and volume of IMH based on aT2* < 20 ms are smaller compared to ssT2*. Thus the method used to quantify IMH from T2* CMR may influence the diagnosis for IMH.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2021) conducted an observational in ST-segment elevation myocardial infarction (STEMI) with reperfusion (n=70). Absolute T2 thresholding (aT2 < 20 ms) vs. Subject-specific T2 (ssT2) was evaluated on Intramyocardial hemorrhage (IMH) volume (%LV) in the acute phase (mean bias of 1.8% LV, p=<0.001). The absolute T2 threshold approach (aT2 < 20 ms) significantly underestimated the volume of intramyocardial hemorrhage compared to the subject-specific T2 method in patients with reperfused STEMI.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: