Key result
High maternal anti-SSA/Ro titers are linked to a ~4% fetal AVB risk versus low titers.
Why the study?
The study was conducted to evaluate the impact of anti-SSA/Ro titers and the utility of ambulatory fetal heart rate and rhythm monitoring in detecting fetal second-degree atrioventricular block.
Does fetal home monitoring and autoantibody titer stratification improve the detection of fetal atrioventricular block in pregnant women with anti-SSA/Ro autoantibodies?
Cohort (n=413)
Does fetal home monitoring and autoantibody titer stratification improve the detection of fetal atrioventricular block in pregnant women with anti-SSA/Ro autoantibodies?
Absolute Event Rate: 3.8% vs 0%
High-titer anti-SSA/Ro antibodies are associated with increased fetal AV block risk, and home fetal heart rate monitoring can reliably detect conduction abnormalities, potentially reducing the need for serial echocardiograms.
High anti-SSA/Ro titers were associated with fetal AVB and home monitoring detected cases; leaves open whether titer-stratified surveillance improves outcomes.
OBJECTIVE: This prospective study of pregnant patients, Surveillance To Prevent AV Block Likely to Occur Quickly (STOP BLOQ), addresses the impact of anti-SSA/Ro titers and utility of ambulatory monitoring in the detection of fetal second-degree atrioventricular block (AVB). METHODS: Women with anti-SSA/Ro autoantibodies by commercial testing were stratified into high and low anti-52-kD and/or 60-kD SSA/Ro titers applying at-risk thresholds defined by previous evaluation of AVB pregnancies. The high-titer group performed fetal heart rate and rhythm monitoring (FHRM) thrice daily and weekly/biweekly echocardiography from 17-26 weeks. Abnormal FHRM prompted urgent echocardiography to identify AVB. RESULTS: Anti-52-kD and/or 60-kD SSA/Ro met thresholds for monitoring in 261 of 413 participants (63%); for those, AVB frequency was 3.8%. No cases occurred with low titers. The incidence of AVB increased with higher levels, reaching 7.7% for those in the top quartile for anti-60-kD SSA/Ro, which increased to 27.3% in those with a previous child who had AVB. Based on levels from 15 participants with paired samples from both an AVB and a non-AVB pregnancy, healthy pregnancies were not explained by decreased titers. FHRM was considered abnormal in 45 of 30,920 recordings, 10 confirmed AVB by urgent echocardiogram, 7 being second-degree AVB, all <12 hours from normal FHRM and within another 0.75 to 4 hours to echocardiogram. The one participant with second/third-degree and two participants with third-degree AVB were diagnosed by urgent echocardiogram >17 to 72 hours from an FHRM. Surveillance echocardiograms detected no AVB when the preceding interval FHRM recordings were normal. CONCLUSION: High-titer antibodies are associated with an increased incidence of AVB. Anti-SSA/Ro titers remain stable over time and do not explain the discordant recurrence rates, suggesting that other factors are required. Fetal heart rate and rhythm (FHRM) with results confirmed by a pediatric cardiologist reliably detects conduction abnormalities, which may reduce the need for serial echocardiograms.
No takes yet. Share an insight, caveat, or question.
Buyon et al. (2023) conducted a cohort in Anti-SSA/Ro pregnancies (n=413). High anti-52-kD and/or 60-kD SSA/Ro titers vs. Low anti-SSA/Ro titers was evaluated on Fetal atrioventricular block (AVB). High anti-SSA/Ro titers in pregnant women were associated with a 3.8% incidence of fetal atrioventricular block, compared to 0% in those with low titers.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: