Key result
Percutaneous balloon release restores stuck mechanical mitral leaflet motion and reduces left atrial pressure to 13 mmHg.
Why the study?
High-risk patients with stuck mechanical mitral valve leaflets have limited treatment options due to the unacceptably high risk of redo surgery.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
Captured external expert commentary on this paper, strongest first. Original sources are linked where available.
“The current study addresses this subset of the population, where surgery or fibrinolysis is not an option. We reported the feasibility of Percutaneous Transcatheter Release of Stuck Mechanical Valve (PETROS) with cerebral embolic protection (CEP) for stuck mitral mechanical valves... In this research, we are reporting the mid-term outcome of the PETROS with CEP.”
“Transcatheter release of the stuck mitral mechanical valve with cerebral embolic protection is an alternative therapy with promising mid-term outcomes where surgery or fibrinolysis is not possible or in failed fibrinolysis subsets.”
Percutaneous transcatheter balloon dilation with cerebral embolic protection can be a successful salvage therapy for a stuck mechanical mitral valve leaflet in patients at prohibitive surgical risk.
A 40-year-old woman with a 29-mm CarboMedics mechanical mitral valve (LivaNova, London, UK) was admitted for congestive heart failure and subsequently developed cardiogenic shock. She was found to have a stuck mechanical mitral valve leaflet (Panels A– C; Arrows indicate stuck leaflet; Supplementary material online, Videos S1 and S2) with severely elevated mean mitral gradient (>30 mmHg), and severe pulmonary artery hypertension (123/39 mmHg, mean 76 mmHg). Because the risk of redo surgery was unacceptably high, transcatheter release of the stuck mechanical mitral valve leaflet was attempted. A cerebral embolic protection device (Sentinel, Boston Scientific, Marlborough, MA, USA) was prepositioned in the brachiocephalic and left carotid arteries. The initial attempt to free the stuck leaflet by simply pushing with catheters was unsuccessful. A stiff 0.014” guidewire (Astato XS 20, Asahi Intecc, Japan) was then threaded between the stuck leaflet and the surgical valve ring. The stuck leaflet was successfully pried open with sequential inflations of 1.2-, 2.0-, 3.0-, 4.0-, and 5.0-mm coronary balloons (Panels D– F; Arrows indicate guidewire and balloons; Supplementary material online, Videos S3 and S4). Near-normal motion of both mechanical mitral valve leaflets was achieved (Panels G– I; Arrow indicates released leaflet; Supplementary material online, Videos S5 and S6). Mean left atrial pressure fell from 34 to 13 mmHg and mean pulmonary artery pressure fell from 65 to 43 mmHg. Substantial thrombus debris was retrieved from the cerebral embolic protection device (Panel J). Her clinical status improved, and she was discharged home.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2020) conducted a case report in Stuck mechanical mitral valve leaflet (n=1). Percutaneous transcatheter release using guidewire and sequential balloon inflations was evaluated on Restoration of leaflet motion and hemodynamics. Percutaneous transcatheter release of a stuck mechanical mitral valve leaflet using sequential balloon inflations successfully restored leaflet motion and reduced left atrial pressure from 34 to 13 mmHg.
Synapse has enriched 10 related papers. Consider them for comparative context: