Key result
Transjugular AVEIR VR leadless pacemaker implantation achieves stable 30-day pacing parameters.
Why the study?
Atrioventricular block is a known complication after transcatheter tricuspid valve replacement, and leadless pacemakers are preferred over transvenous systems to avoid interference with the valve prosthesis.
Case Report (n=1)
No
Leadless pacemaker implantation via the right internal jugular vein after transcatheter tricuspid valve replacement is feasible and safe when combined with tailored fluoroscopic projections and full advancement of the protective sleeve to prevent device entanglement in the valve frame.
Answers are grounded in this paper and cite their sources.
May support jugular leadless pacing post-TTVR in select cases; leaves open need for prospective safety data.
BACKGROUND: Tricuspid valve disease is gaining clinical significance, with transcatheter tricuspid valve replacement (TTVR) emerging as a viable alternative to surgery. Atrioventricular block is a known postprocedural complication. To avoid interference with the valve prosthesis, leadless pacemakers (LPMs) are preferred over transvenous systems. CASE SUMMARY: An 87-year-old woman developed symptomatic bradycardic atrial fibrillation 3 months after TTVR with an Evoque prosthesis (Edwards Lifesciences). Given her age and comorbidities, an AVEIR VR (Abbott Medical) LPM was implanted via right jugular vein approach, chosen because of the orientation of the prosthesis. During the first attempt, the pacemaker's helix became entangled in the valve frame despite the use of a protective sleeve. The device was safely retrieved, and a second attempt was successful. Postimplantation imaging confirmed preserved valve function. DISCUSSION: This case underscores the importance of individualized procedural planning for LPM implantation after TTVR. The jugular approach, combined with tailored fluoroscopic angulation, can improve catheter control and reduce the risk of prosthesis interaction. TAKE-HOME MESSAGE: LPM implantation after TTVR is feasible. Optimal access selection, imaging strategy, and sheath handling are essential to minimize complications.
No takes yet. Share an insight, caveat, or question.
Augustin et al. (2025) conducted a case report in Symptomatic bradycardic atrial fibrillation 3 months after transcatheter tricuspid valve replacement (TTVR) (n=1). AVEIR VR leadless pacemaker implantation via right internal jugular vein approach was evaluated on Successful leadless pacemaker implantation with preserved tricuspid valve prosthesis function and stable pacing parameters. AVEIR VR leadless pacemaker implantation via the right jugular vein succeeded on the second attempt after advancing the protective sleeve, achieving stable 30-day pacing.
Synapse has enriched 10 related papers. Consider them for comparative context: