Key result
Exhaled acetone concentration >1.05 ppm was significantly associated with elevated pulmonary capillary wedge pressure (≥18 mmHg) in patients with non-ischemic chronic heart failure (AUC 0.726).
Why the study?
Does exhaled acetone concentration correlate with hemodynamic severity in patients with non-ischemic chronic heart failure?
Cross-Sectional (n=119)
No
Does exhaled acetone concentration correlate with hemodynamic severity in patients with non-ischemic chronic heart failure?
Exhaled acetone concentration is a potential noninvasive biomarker that correlates with hemodynamic severity and elevated PCWP in non-ischemic chronic heart failure.
Exhaled acetone may signal elevated PCWP in non-ischemic HF; hypothesis-generating and requires prospective validation before clinical use.
BACKGROUND: We hypothesized that exhaled acetone concentration (EAC), reflecting altered blood ketone body metabolism and increased acetone exhaust because of pulmonary congestion in heart failure (HF), would correlate with hemodynamic parameters in patients with non-ischemic chronic HF. METHODS AND RESULTS: We prospectively enrolled 102 non-ischemic HF patients with New York Heart Association (NYHA) class I-III. Exhaled breath was collected after an overnight fast. Echocardiography and cardiac catheterization were performed in all patients. We also enrolled 17 control patients without HF. EAC in the HF patients was significantly higher than that in the control patients (median EAC; 0.53 vs. 0.38 ppm, P=0.012). EAC positively correlated with blood total ketone bodies (r=0.454, P<0.001), NYHA class (r=0.489, P<0.001), and plasma B-type natriuretic peptide (r=0.316, P=0.001). Right heart catheterization revealed that EAC significantly correlated with pulmonary capillary wedge pressure (PCWP, r=0.377, P<0.001). Receiver-operating characteristic analysis revealed that EAC >1.05 ppm was associated with PCWP ≥18 mmHg (area under the curve [AUC] 0.726, sensitivity 50%, specificity 89%). EAC was shown to be a comparable diagnostic biomarker for HF to BNP (AUC 0.760, sensitivity 80%, specificity 70%). CONCLUSIONS: EAC may be a novel noninvasive biomarker that correlates hemodynamic severity in non-ischemic chronic HF. (Circ J 2016; 80: 1178-1186).
No takes yet. Share an insight, caveat, or question.
Yokokawa et al. (2016) conducted a cross-sectional in Non-ischemic chronic heart failure (n=119). Exhaled acetone concentration vs. Low exhaled acetone concentration or non-heart failure controls was evaluated on Diagnostic accuracy for pulmonary capillary wedge pressure (PCWP) ≥ 18 mmHg (AUC 0.726, 95% CI 0.567-0.886, p=0.019). Exhaled acetone concentration >1.05 ppm was significantly associated with elevated pulmonary capillary wedge pressure (≥18 mmHg) in patients with non-ischemic chronic heart failure (AUC 0.726).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: