Key result
ICE-guided focused endocardial surface registration reduced the mean ablation point-to-CT image distance compared to landmark registration.
Why the study?
Does ICE-guided focused endocardial surface registration improve alignment between electroanatomical maps and 3D CT/MR images compared to landmark registration in patients undergoing AF ablation?
Cohort (n=40)
Does ICE-guided focused endocardial surface registration improve alignment between electroanatomical maps and 3D CT/MR images compared to landmark registration in patients undergoing AF ablation?
ICE-guided focused endocardial surface registration provides superior alignment between CT/MR images and electroanatomical maps compared to landmark registration during AF ablation.
Answers are grounded in this paper and cite their sources.
Focused surface registration may improve alignment accuracy in AF ablation; leaves open effects on clinical outcomes.
INTRODUCTION: Image integration is used in AF ablation procedures. To maximize the efficacy of image integration, it is essential to obtain good alignment between the electroanatomical map and the 3D image of the heart. In the present study, we compared an ICE-guided landmark registration with an ICE-guided focused endocardial surface registration. METHODS AND RESULTS: In 20 patients, registration was based on posterior landmarks acquired under ICE guidance (group A); in another 20 matched patients, a new ICE-guided focused endocardial surface registration technique was used (group B). In these latter patients, a single landmark was acquired in the inferior part of the LIPV, and several surface points were recorded in the posterior area of the left PV antrum and around the antra of the right PVs. The mean ablation point-to-CT image distance was calculated in both groups. In group A, the mean landmark point-to-CT image distance was also calculated after adding the surface registration. The mean landmark point-to-CT image distance was 4.62 +/- 1.65 mm and increased to 7.66 +/- 2.44 mm when surface registration was added. The ablation point-to-CT image distance was significantly shorter in group B (1.73 +/- 0.29 mm vs 3 +/- 0.99 mm; P < 0.001). CONCLUSIONS: This ICE-guided focused endocardial surface registration seems to be superior to landmark registration in achieving a better alignment between the CT/MR image and the electroanatomical map. The concurrent use of standard surface registration may result in rotation of the atrial chamber.
No takes yet. Share an insight, caveat, or question.
Rossillo et al. (2008) conducted a cohort in Atrial Fibrillation (n=40). ICE-guided focused endocardial surface registration vs. ICE-guided landmark registration was evaluated on Mean ablation point-to-CT image distance (p=< 0.001). ICE-guided focused endocardial surface registration reduced the mean ablation point-to-CT image distance compared to landmark registration.
Synapse has enriched 10 related papers. Consider them for comparative context: