July 8, 2026Buildings0 citationsOpen Access

Thermal Optimization of a Glazing–PCM Integrated Balcony Sunspace for Cold-Climate Residential Buildings

View Full Paper
XYXingbo YaoZQZhi QiaoYLY Liu

Key Points

  • This study aims to improve indoor thermal comfort and reduce energy demands for cold-climate balcony sunspaces using glazing and PCM.
  • Conducted dynamic simulations to assess balcony sunspace configurations.
  • Compared five glazing systems under various orientations for thermal performance.
  • Introduced a 9C–PCM–9C partition wall and measured its impact on thermal metrics.
  • Optimal glazing system improved thermal comfort ratio by 4.15–5.24 percentage points.
  • Reduced annual heating demand by 13.78–15.80 kWh/m2; cooling demand by 6.16–7.21 kWh/m2.
  • PCM integration further increased thermal comfort by 2.05–2.50 percentage points and reduced heating/cooling demand by 4.80–5.10 kWh/m2 and 1.64–1.76 kWh/m2, respectively.

Abstract

Modern residential balconies have the potential to function as passive solar buffer spaces, yet their thermal performance in cold-region high-rise apartments remains insufficiently explored. This study proposes a stepwise glazing–phase change material (PCM) integrated balcony sunspace strategy for a typical high-rise residential apartment in Xi’an, China. Dynamic simulations were conducted to evaluate the effects of balcony orientation, glazing system, PCM melting temperature, and PCM thickness on indoor thermal comfort and annual heating and cooling demand. First, an open living room-connected balcony was used as the benchmark case, and five glazing systems were compared under southwest-, south-, and southeast-facing orientations. Then, based on the optimal glazing system, a 9C–PCM–9C partition wall was introduced between the enclosed balcony sunspace and the living room. The results showed that the optimal glazing system increased the annual thermal comfort ratio by 4.15–5.24 percentage points and reduced annual heating and cooling demand by 13.78–15.80 kWh/m2 and 6.16–7.21 kWh/m2, respectively. Further PCM integration achieved additional improvements, with 21 °C + 30 mm identified as the optimal configuration for all orientations. Compared with the glazing-only case, it increased thermal comfort by 2.05–2.50 percentage points and reduced heating and cooling demand by 4.80–5.10 kWh/m2 and 1.64–1.76 kWh/m2, respectively. The findings provide a practical passive design strategy for climate-responsive balcony sunspaces in cold-region residential buildings.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yao et al. (2026) studied this question.

synapsesocial.com/papers/6a4de9e4d2ea289ef6283e6bhttps://doi.org/10.3390/buildings16132672
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Assessment of Phase Change Materials Incorporation into Construction Commodities for Sustainable and Energy-Efficient Building Applications2025 · 11 citations
  2. 2Dynamic effect of balcony thermal bridges on the energy performance of a high-rise residential building in Canada2016 · 38 citations
  3. 3Multiscale coupled hygrothermal performance of PCM-integrated timber building envelope2026 · 1 citations
  4. 4Rural household energy consumption of farmers and herders in the Qinghai-Tibet Plateau2019 · 70 citations
  5. 5On the use of 3D printing to enhance the thermal performance of building envelope – A review2024 · 26 citations