Demonstrates improved power delivery efficiency in AI servers, highlighting potential for energy savings.
In recent years, the rapid evolution of large artificial intelligence (AI) models has placed unprecedented demands on the computing power of data center servers, driving an explosive growth in data center computing requirements. The power consumption of core computing components, represented by GPUs, has surged dramatically. When facing extremely high power densities, the traditional 12 V single-voltage power delivery architecture exposes severe limitations, including increased transmission link losses, thermal management difficulties, and low system efficiency. To address these challenges, this paper proposes and designs a hierarchical 54 V/12 V dual-plane multi-phase DC power delivery architecture for high-computing-power AI servers. By conducting refined hierarchical identification of system loads, this architecture introduces a 54 V high-voltage DC power plane for high-power loads while retaining the 12 V power plane for conventional loads. Within each power plane, multi-phase interleaved parallel Buck converters integrated with Turbo-COT control strategies and high-density DrMOS are deployed. Experimental results demonstrate that this power architecture exhibits excellent electrical characteristics: under steady-state conditions, the peak-to-peak (PK-PK) ripple voltage fluctuation amplitude of the 54 V power plane under different loads is compressed to between ±0.22% and ±0.26%, while the PK-PK ripple voltage fluctuation amplitude of the 12V power plane under different loads reaches ±0.66% to ±0.68%; in dynamic load step (0–50% and 50–100%) tests, the PK-PK voltage fluctuations of the 54 V plane are ±1.42% and ±1.33%, whereas the PK-PK voltage fluctuations of the 12 V power plane are ±2.36% and ±1.83%. Furthermore, the peak conversion efficiency of the 54 V power plane approaches 97%, and the maximum efficiency of the 12 V power plane reaches 94%, showing a measurable efficiency improvement under the tested conditions. The hierarchical multi-phase power delivery technology comprehensively reduces power supply link losses and enhances power stability, providing an important theoretical basis and engineering reference for the design of next-generation high-density AI servers and the optimization of green, energy-saving networks in data centers.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: