Key result
An abnormal exercise test was associated with a higher catheterization referral rate than a normal test (42.5% vs 4.0%; OR 14.6, 95% CI 10.7-19.9), which markedly alters adjusted diagnostic accuracy.
Why the study?
Does adjusting for referral bias change the diagnostic performance of exercise echocardiography and myocardial perfusion imaging in patients with suspected coronary artery disease?
Meta-Analysis (n=49,006)
Does adjusting for referral bias change the diagnostic performance of exercise echocardiography and myocardial perfusion imaging in patients with suspected coronary artery disease?
Odds Ratio: 14.6 (95% CI 10.7–19.9)
Absolute Event Rate: 42.5% vs 4%
Adjusting for referral bias reveals that exercise echocardiography and myocardial perfusion imaging are considerably less sensitive and more specific for coronary artery disease than previously reported.
Referral bias may markedly overestimate exercise test sensitivity for CAD; challenges unadjusted accuracy estimates in practice and research.
BACKGROUND: Exercise testing with echocardiography or myocardial perfusion imaging is widely used to risk-stratify patients with suspected coronary artery disease. However, reports of diagnostic performance rarely adjust for referral bias, and this practice may adversely influence patient care. Therefore, we evaluated the potential impact of referral bias on diagnostic effectiveness and clinical decision-making. METHODS AND RESULTS: Searching PubMed and EMBASE (1990-2012), 2 investigators independently evaluated eligibility and abstracted data on study characteristics and referral patterns. Diagnostic performance reported in 4 previously published meta-analyses of exercise echocardiography and myocardial perfusion imaging was adjusted using pooled referral rates and Bayesian methods. Twenty-one studies reported referral patterns in 49 006 patients (mean age 60.7 years, 39.6% women, and 0.8% prior history of myocardial infarction). Catheterization referral rates after normal and abnormal exercise tests were 4.0% (95% CI, 2.9% to 5.0%) and 42.5% (36.2% to 48.9%), respectively, with odds ratio for referral after an abnormal test of 14.6 (10.7 to 19.9). After adjustment for referral, exercise echocardiography sensitivity fell from 84% (80% to 89%) to 34% (27% to 41%), and specificity rose from 77% (69% to 86%) to 99% (99% to 100%). Similarly, exercise myocardial perfusion imaging sensitivity fell from 85% (81% to 88%) to 38% (31% to 44%), and specificity rose from 69% (61% to 78%) to 99% (99% to 100%). Summary receiver operating curve analysis demonstrated only modest changes in overall discriminatory power but adjusting for referral increased positive-predictive value and reduced negative-predictive value. CONCLUSIONS: Exercise echocardiography and myocardial perfusion imaging are considerably less sensitive and more specific for coronary artery disease after adjustment for referral. Given these findings, future work should assess the comparative ability of these and other tests to rule-in versus rule-out coronary artery disease.
No takes yet. Share an insight, caveat, or question.
Ladapo et al. (2013) conducted a meta-analysis in Suspected coronary artery disease (n=49,006). Abnormal exercise test vs. Normal exercise test was evaluated on Catheterization referral (OR 14.6, 95% CI 10.7-19.9). An abnormal exercise test was associated with a higher catheterization referral rate than a normal test (42.5% vs 4.0%; OR 14.6, 95% CI 10.7-19.9), which markedly alters adjusted diagnostic accuracy.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: