Key result
Point-of-care lung ultrasound shows ~20% higher sensitivity than chest radiography for diagnosing pulmonary edema.
Meta-Analysis (n=1,827)
Relative Risk: 1.2 (95% CI 1.08–1.34)
Absolute Event Rate: 0.88% vs 0.73%
p-value: p=<.001
Importance: Standard tools used to diagnose pulmonary edema in acute decompensated heart failure (ADHF), including chest radiography (CXR), lack adequate sensitivity, which may delay appropriate diagnosis and treatment. Point-of-care lung ultrasonography (LUS) may be more accurate than CXR, but no meta-analysis of studies directly comparing the 2 tools was previously available. Objective: To compare the accuracy of LUS with the accuracy of CXR in the diagnosis of cardiogenic pulmonary edema in adult patients presenting with dyspnea. Data Sources: A comprehensive search of MEDLINE, Embase, and Cochrane Library databases and the gray literature was performed in May 2018. No language or year limits were applied. Study Selection: Study inclusion criteria were a prospective adult cohort of patients presenting to any clinical setting with dyspnea who underwent both LUS and CXR on initial assessment with imaging results compared with a reference standard ADHF diagnosis by a clinical expert after either a medical record review or a combination of echocardiography findings and brain-type natriuretic peptide criteria. Two reviewers independently assessed the studies for inclusion criteria, and disagreements were resolved with discussion. Data Extraction and Synthesis: Reporting adhered to the Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy and the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Two authors independently extracted data and assessed the risk of bias using a customized QUADAS-2 tool. The pooled sensitivity and specificity of LUS and CXR were determined using a hierarchical summary receiver operating characteristic approach. Main Outcomes and Measures: The comparative accuracy of LUS and CXR in diagnosing ADHF as measured by the differences between the 2 modalities in pooled sensitivity and specificity. Results: The literature search yielded 1377 nonduplicate titles that were screened, of which 43 articles (3.1%) underwent full-text review. Six studies met the inclusion criteria, representing a total of 1827 patients. Pooled estimates for LUS were 0.88 (95% Cl, 0.75-0.95) for sensitivity and 0.90 (95% Cl, 0.88-0.92) for specificity. Pooled estimates for CXR were 0.73 (95% CI, 0.70-0.76) for sensitivity and 0.90 (95% CI, 0.75-0.97) for specificity. The relative sensitivity ratio of LUS, compared with CXR, was 1.2 (95% CI, 1.08-1.34; P < .001), but no difference was found in specificity between tests (relative specificity ratio, 1.0; 95% CI, 0.90-1.11; P = .96). Conclusions and Relevance: The findings suggest that LUS is more sensitive than CXR in detecting pulmonary edema in ADHF; LUS should be considered as an adjunct imaging modality in the evaluation of patients with dyspnea at risk of ADHF.
No takes yet. Share an insight, caveat, or question.
Maw et al. (2019) conducted a meta-analysis in Acute Decompensated Heart Failure (ADHF) (n=1,827). Point-of-care lung ultrasonography (LUS) vs. Chest radiography (CXR) was evaluated on Comparative accuracy in diagnosing ADHF measured by differences in pooled sensitivity and specificity (Relative sensitivity ratio 1.2, 95% CI 1.08-1.34, p=<.001). Point-of-care lung ultrasonography was more sensitive than chest radiography (relative sensitivity ratio 1.2; 95% CI 1.08-1.34; P<.001) for detecting pulmonary edema in adults with dyspnea.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: