Key result
Water-saturation MRI with computer segmentation provided accurate quantification of visceral adipose tissue, showing good correlation with manual techniques and high reproducibility.
Why the study?
Does water-saturation MRI with computer segmentation accurately and efficiently quantify visceral adipose tissue compared to manual techniques?
Does water-saturation MRI with computer segmentation accurately and efficiently quantify visceral adipose tissue compared to manual techniques?
Water-saturation MRI combined with computer segmentation provides an accurate, highly reproducible, and time-efficient method for quantifying visceral adipose tissue.
Answers are grounded in this paper and cite their sources.
May support automated VAT quantification in small cohorts; leaves open validation in larger studies before clinical adoption.
PURPOSE: To describe and evaluate the accuracy of water-saturation MRI and a computer segmentation program for quantification of visceral adipose tissue (VAT). MATERIALS AND METHODS: MRI was performed on five patients with whole-volume coverage of the abdomen using two different sequences: 1) a T1-weighted spoiled gradient-echo breath-hold sequence (non-water-saturation) and 2) a T1-weighted spoiled gradient-echo water-saturation breath-hold sequence (water-saturation). The computer segmentation program analyzed the data and calculated VAT volumes (cm3) from both sequences. The data from one patient were additionally processed with the use of a manual technique. The intrastudy reproducibility of the proposed method using the water-saturation MRI sequence and the computer segmentation technique was tested by repeated measures of the automated system analysis (x 10) on MRI data from a single subject to calculate variability. RESULTS: VAT volumes measured by the water-saturation MRI sequences were consistently greater than those measured by the non-water-saturation sequences. Comparison of VAT volumes derived from the water-saturation images and measured by the computer segmentation technique vs. the manual technique showed good correlation (K = 0.8), with a significant time-saving benefit associated with the automated method (5 minutes vs. 1 hour). There was poor correlation between VAT volume measurement calculated by the manual technique and the computer segmentation technique using non-water-saturation images. The reproducibility of the computer segmentation technique using data derived from water-saturation images was high, with a low variability (+/- 5%). CONCLUSION: The results obtained demonstrate that the proposed method may be able to provide accurate quantification of VAT in a highly reproducible and efficient manner.
No takes yet. Share an insight, caveat, or question.
Armao et al. (2006) studied this question. Water-saturation MRI and computer segmentation vs. Non-water-saturation MRI and manual technique was evaluated on Accuracy and reproducibility of visceral adipose tissue (VAT) volume quantification (K = 0.8). Water-saturation MRI with computer segmentation provided accurate quantification of visceral adipose tissue, showing good correlation with manual techniques and high reproducibility.