July 11, 2026Fatigue of Aircraft StructuresOpen Access

Fatigue-Induced Crack an Aircraft Fire Extinguisher Outlet Discharge System: A Maintenance Case Study of an Airbus A330-900

View Full Paper
Ask AI
Bookmark
Share

Authors

GSGunawan SaktiLSLaila Bungas SarwaniHPHadi Prayitno

Discussion

Loading...

Member takes

Overview

Case study analyzes crack in fire extinguisher discharge system, indicating maintenance importance.

Key Points

  • This study aims to analyze a crack detected in the fire extinguisher outlet of an Airbus A330-900 and its implications for safety.
  • Applied a real maintenance case study approach integrating inspection records and visual observations.
  • Conducted fatigue interpretation and Paris Law-based crack growth simulation using MATLAB.
  • Evaluated safety factors and performed Failure Mode and Effects Analysis (FMEA).
  • Crack length was less than 5 mm after approximately 5,642 flight cycles with a safety factor of 1.2.
  • MATLAB simulation predicted crack growth aligned with actual flight cycle data, confirming fatigue-induced propagation.
  • Post-replacement testing showed no observable leakage and restored normal flow characteristics.

Cite This Study

Sakti et al. (2026) studied this question.

synapsesocial.com/papers/6a51e168c18d7f28ca5010d3https://doi.org/10.2478/fas-2025-0009