Answers are grounded in this paper and cite their sources.
Identifies local heat-risk exposure in beef cattle barns, suggesting targeted assessments are necessary.
Barn-level monitoring may mask local heat-risk exposure in open-sided beef cattle barns. This study evaluated a long-range wireless multi-point monitoring framework for pen-scale heat-risk mapping in a commercial open-sided double-row barn during the hot season. Environmental data were continuously collected from representative front, middle, and rear pens, and the temperature–humidity index (THI) was matched with respiration rate, per-head daily water intake, and descriptive body-weight records. The data completeness of the main analytical nodes was 99.75–99.88%. Mixed-effects models showed that the middle and rear pens had higher daily and daytime THI intensity than the front pen (p < 0.001), whereas the daytime duration of THI ≥ 78 was similar among pens. The rear–front THI difference was amplified during 10:00–16:00 (β = 1.19, p = 0.006). Respiration rate increased by 1.25 breaths min−1 for each one-unit increase in THI (95% CI: 0.92–1.57, p < 0.001). Per-head daily water intake was more strongly associated with daily mean THI than with daily maximum THI. These findings indicate that pen-scale monitoring can identify local thermal heterogeneity and provide a data basis for targeted environmental assessment in open-sided beef cattle barns.
No takes yet. Share an insight, caveat, or question.
Yi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: