Answers are grounded in this paper and cite their sources.
Retrospective study shows significant improvement in MRI image quality using wavelet filtering in patients after hip replacement, suggesting better diagnostic capabilities.
Background Slice encoding for metal artifact correction (SEMAC) is used in MRI for total hip arthroplasties for metal artifact reduction. However, ripple artifacts often arise near the implant, impairing diagnosis in affected regions. Hypothesis Applying a wavelet domain filter (WD‐Filter) might reduce ripple artifacts and improve image quality. Study Type Retrospective. Subjects 100 patients with primary total hip arthroplasty (female: 51, mean age: (64 ± 13) years; male: 49, mean age: (65 ± 13) years) who underwent clinically indicated MRI using compressed sensing SEMAC. Field Strength/Sequences 1.5 T; compressed sensing‐accelerated turbo spin‐echo (TSE)‐based SEMAC sequence. Assessment Three readers rated 250 ripple artifacts before and after applying the WD‐filter. 4‐point Likert scales were used for the intensity of ripple artifacts (Likert‐RA, “none”: 1, “mild”: 2, “moderate”: 3, “severe”: 4) and the image quality (Likert‐IQ, “poor”: 1, “moderate”: 2, “good”: 3, “excellent”: 4). The relative reduction of the signal intensity standard deviation () was measured in a region of interest (ROI) containing the ripple artifact. Statistical Tests Inter‐reader agreement was assessed with Fleiss' kappa, with 95% confidence intervals. Differences between pre‐ and post‐filter ratings (Likert‐RA and Likert‐IQ) were evaluated using the Wilcoxon signed‐rank test, while was compared using a two‐sided paired t ‐test. A p value of less than 0.05 indicated statistical significance. Results Prior to WD‐Filter application, ripple artifacts were rated as “severe”, as “moderate”, and as “mild”. After filtering, artifacts were rated as “none”, and as “mild”. Upon filter application, Likert‐RA and Likert‐IQ significantly improved from to and to , respectively, with a large effect size ( r > 0.89) and “almost perfect” inter‐rater agreement (kappa range: 0.86–0.96). The filtered images showed a significantly reduced compared to the unfiltered images (relative change: ). Data Conclusion The WD‐Filter effectively reduced ripple artifacts in MRI of total hip arthroplasty and improved image quality. Evidence Level 3. Technical Efficacy Stage 3.
No takes yet. Share an insight, caveat, or question.
Deck et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: