Answers are grounded in this paper and cite their sources.
Tests the performance of a repaired HTS insert in hybrid magnets, suggesting implications for magnetic field stability.
This study is a sequel to our previous study on a 38 mm diameter cold bore metal-as-insulation (MI) HTS insert that reached 32.5 T in a 18 T background magnetic field. For refurbishing, 7 MI double-pancake (DP) coils were re-wound with used REBCO tapes to just replace the damaged HTS pieces by new ones at inner junctions. 2 DP coils were fully fabricated using new REBCO tapes. The new assembled insert was then tested under various background magnetic fields at 4.2 K. The key focuses of this paper are: 1) the damages in the DP coils; 2) their repair; 3) the characteristics resistance change of the insert; 4) the resistance value of each DP coil; 5) the maximum field of the HTS-resistive hybrid magnet; and 6) the field stability estimation of the hybrid by NMR characterization.
No takes yet. Share an insight, caveat, or question.
Song et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: