Key result
Intraoperative hypotension during pacemaker placement for congenital complete heart block occurred in 71.4% of neonates with congenital heart defects versus 23.5% with normal hearts.
Why the study?
What are the hemodynamic complications during anesthetic management for pacemaker placement in neonates with congenital complete heart block?
Observational (n=24)
No
What are the hemodynamic complications during anesthetic management for pacemaker placement in neonates with congenital complete heart block?
Anesthesia for pacemaker placement in neonates with congenital complete heart block carries a high risk of hemodynamic instability, particularly in those with coexisting congenital heart defects.
Answers are grounded in this paper and cite their sources.
Neonates with congenital heart defects may warrant heightened vigilance for hypotension; leaves open whether tailored protocols reduce risk in congenital complete heart block.
BACKGROUND: Anesthesia for patients with complete heart block can be associated with significant hemodynamic instability. The aim of this study is to review our anesthetic experience of neonates with congenital complete heart block (CCHB) who underwent placement of either a temporary epicardial pacing system or a permanent epicardial pacemaker. METHODS: The anesthetic management of neonates with CCHB who underwent pacemaker placement at a single institution over a 16-year period was reviewed. RESULTS: Twenty-four neonates were identified, 17 with a structurally normal heart (NL) and seven with associated congenital heart defects (CHD). Median (range) gestational age was 36.9 (26-41) weeks, birth weight 2.9 (1.0-4.1) kg, and baseline heart rate 47 (38-80) b.min(-1). A temporary epicardial pacing system was placed in six patients (four CHD, two NL; P = 0.003) following institution of mechanical ventilation and inotropic support for a low cardiac output state, and a permanent epicardial pacemaker was placed in 18 patients. Atropine 0.02 mg.kg(-1) IV prior to induction (n = 5) increased heart rate less than 20%. Intraoperative hypotension was documented in nine neonates, five of seven with CHD and four of 17 with NL (P = 0.02). In four patients (44%) hypotension occurred despite concurrent inotropic support. Intraoperative cardiac arrest occurred in one neonate, necessitating institution of extracorporeal membrane oxygenation. Two patients (8.3%) died in hospital from complex CHD and complications of prematurity. CONCLUSIONS: Early institution of mechanical ventilation, inotropic support and pacing are necessary in the neonate with CCHB and poor hemodynamic function, particularly with coexisting CHD or prematurity.
No takes yet. Share an insight, caveat, or question.
Kussman et al. (2005) conducted an observational in Congenital complete heart block (n=24). Associated congenital heart defects vs. Structurally normal heart was evaluated on Intraoperative hypotension (p=0.02). Intraoperative hypotension during pacemaker placement for congenital complete heart block occurred in 71.4% of neonates with congenital heart defects versus 23.5% with normal hearts.
Synapse has enriched 10 related papers. Consider them for comparative context: