Key result
Quantitative flow ratio accurately identified functionally significant lesions (FFR ≤0.80) irrespective of vessel size, with an AUC of 0.89 in vessels ≤2.8 mm and 0.81 in vessels >2.8 mm.
Why the study?
It was uncertain whether reference vessel dimensions affect functional coronary lesion assessment using quantitative flow ratio.
Does quantitative flow ratio (QFR) accurately assess functional coronary lesion severity compared to fractional flow reserve (FFR) in patients with small-vessel disease?
Observational (n=436)
Does quantitative flow ratio (QFR) accurately assess functional coronary lesion severity compared to fractional flow reserve (FFR) in patients with small-vessel disease?
Absolute Event Rate: 0.89% vs 0.81%
p-value: p=<0.001
Quantitative flow ratio (QFR) provides accurate functional assessment of intermediate coronary lesions irrespective of reference vessel diameter, including in small vessels.
QFR may inform small-vessel lesion assessment; extends diagnostic validation but leaves clinical adoption open.
BACKGROUND: Quantitative flow ratio (QFR) has recently been introduced as a novel, less-invasive, adenosine-free measure for functional coronary lesion assessment. Whether reference vessel dimensions affect functional lesion assessment is uncertain. METHODS: A total of 436 patients with 516 interrogated coronary vessels by means of FFR were included in the study. Patients were dichotomized according to the median reference vessel diameter (group 1: ≤2.8 mm and group 2: >2.8 mm). QFR analyses were performed offline at the institution's core laboratories. RESULTS: Reference vessel diameter was 2.5 [2.3-2.7] mm in group 1 and 3.3 [3.0-3.6] mm in group 2. Diameter stenosis (41.4 [36.4-47.6] % vs. 41.4 [36.4-45.7] %, p = .20) did not differ among groups. Median FFR values were lower in group 1 (0.87 [0.81-0.92]) as compared with group 2 (0.89 [0.84-0.93], p = .001). Consistently, QFR values were lower in group 1 (0.88 [0.82-0.92]) than in group 2 (0.91 [0.85-0.94], p = .001). The proportions of functionally significant coronary lesions as defined by FFR ≤0.80 were 24.1% and 14.2% in groups 1 and 2 (p = .005), and as defined by cQFR ≤0.80 20.4% and 11.8% (p = 0.009), respectively. In ROC analysis for an FFR ≤.80, the AUC was 0.89 (95% CI 0.85-0.93, p < .001) in group 1 and 0.81 (95% CI 0.76-0.86, p < .001) in group 2. CONCLUSIONS: These results suggest that QFR measurements are accurate irrespective of the reference vessel diameter. Future studies are needed to elucidate the higher percentage of functionally significant lesions observed in small vessels despite a similar angiographic lesion severity.
No takes yet. Share an insight, caveat, or question.
Erbay et al. (2019) conducted an observational in Intermediate coronary lesions (n=436). Reference vessel diameter ≤2.8 mm vs. Reference vessel diameter >2.8 mm was evaluated on Diagnostic accuracy of QFR for FFR ≤0.80 (AUC) (p=<0.001). Quantitative flow ratio accurately identified functionally significant lesions (FFR ≤0.80) irrespective of vessel size, with an AUC of 0.89 in vessels ≤2.8 mm and 0.81 in vessels >2.8 mm.