Key result
Dobutamine challenge drops diastolic FFR ~13%, improving detection of hemodynamically relevant myocardial bridges.
Why the study?
Does diastolic FFR with dobutamine challenge improve the identification of hemodynamic relevance in symptomatic patients with myocardial bridging compared to mean FFR?
Observational (n=12)
Does diastolic FFR with dobutamine challenge improve the identification of hemodynamic relevance in symptomatic patients with myocardial bridging compared to mean FFR?
Answers are grounded in this paper and cite their sources.
Diastolic FFR with dobutamine challenge is superior to mean FFR for assessing the hemodynamic significance of myocardial bridges, as systolic pressure overshooting causes errors in mean FFR.
OBJECTIVES This study reports a comparative assessment of the hemodynamic relevance of myocardial bridges (MB) using two modalities of fractional flow reserve (FFR), with and without concomitant inotropic challenge. BACKGROUND Extravascular coronary compression by means of MB is modulated by myocardial inotropism and causes intracoronary systolic pressure overshooting and negative systolic gradients across the MB. The former characteristic suggests that adequate hemodynamic assessment of MB should include inotropic stimulation. The latter characteristic might interfere with FFR by decreasing the mean pressure gradient. METHODS We compared the hemodynamic relevance of 12 lone MB in symptomatic patients using conventional (mean) and diastolic FFR. Diastolic FFR was obtained from post-processed, digitally acquired electrocardiogram and pressure signals. Previously validated cut off values of 0.75 (mean FFR) and 0.76 (diastolic FFR) for hemodynamic relevance were used. Measurements were performed at baseline and after incremental intravenous dobutamine doses. RESULTS Fractional flow reserve decreased during dobutamine challenge: mean FFR was 0.90 +/- 0.04 at baseline and 0.84 +/- 0.06 after dobutamine (p = 0.0008); similarly, diastolic FFR was 0.88 +/- 0.05 and 0.77 +/- 0.10 before and after dobutamine, respectively (p = 0.0006). Diastolic FFR identified hemodynamic relevance in five patients, whereas mean FFR did so in only one patient. The discrepancy between mean FFR and diastolic FFR increased with dobutamine challenge: the ratio of mean FFR/diastolic FFR was 1.03 at baseline and 1.09 after dobutamine (p = 0.02). During the administration of dobutamine, the discrepancy was inversely related to the systolic pressure gradient (r = 0.58, P = 0.04). CONCLUSIONS Physiologic assessment of MB should include dobutamine challenge. Because the overshooting of systolic pressure interferes with and is a cause of error in FFR measurements based on mean pressures, diastolic FFR appears to be the technique of choice for MB assessment, whereas mean FFR should be used with caution.
No takes yet. Share an insight, caveat, or question.
Escaned et al. (2003) conducted an observational in Myocardial bridging (n=12). Dobutamine challenge vs. Baseline (without dobutamine) was evaluated on Diastolic fractional flow reserve (FFR) (p=0.0006). Dobutamine challenge decreased diastolic FFR from 0.88 to 0.77, identifying hemodynamic relevance in 5 of 12 patients compared to only 1 patient using mean FFR.
Synapse has enriched 10 related papers. Consider them for comparative context: