Key result
Lower left atrial total emptying fraction is linked to ~12% lower odds of low-voltage areas.
Why the study?
Pre-procedural prediction of low-voltage areas targeted during radiofrequency catheter ablation for atrial fibrillation remains challenging.
Does left atrial total emptying fraction measured by CMR predict the presence of low-voltage areas in patients with atrial fibrillation undergoing ablation?
Cohort (n=259)
Blinded evaluators
No
Does left atrial total emptying fraction measured by CMR predict the presence of low-voltage areas in patients with atrial fibrillation undergoing ablation?
Odds Ratio: 0.885 (95% CI 0.846–0.926)
p-value: p=<0.001
Left atrial total emptying fraction assessed by pre-procedural CMR imaging can help predict the presence of arrhythmogenic low-voltage areas in patients with atrial fibrillation, aiding in procedural planning for catheter ablation.
LA emptying fraction and CHA2DS2-VASc score were associated with low-voltage areas; leaves open utility for ablation planning pending prospective validation.
AIMS: Low-voltage areas (LVAs) found during left atrial (LA) electroanatomical mapping are increasingly targeted by radiofrequency catheter ablation (RFCA) on top of pulmonary vein isolation to improve arrhythmia-free survival in patients with atrial fibrillation (AF). However, pre-procedural prediction of LVAs remains challenging. The purpose of the present study was to describe the association between parameters of LA function and dimensions, respectively, derived from pre-procedural cardiovascular magnetic resonance (CMR) imaging, and the presence of LVAs on LA voltage mapping. METHODS AND RESULTS: Patients who underwent first-time RFCA for paroxysmal or persistent AF and who were in stable sinus rhythm during pre-procedural CMR imaging were included in this study. Cardiovascular magnetic resonance-derived parameters of LA function and dimensions were calculated. Low-voltage areas were defined as areas with bipolar voltage amplitudes of ≤0.5 mV on electroanatomical mapping. In total, 259 consecutive patients were included in this analysis. Low-voltage areas were found in 25 of 259 patients (9.7%). Compared with those without LVAs, patients with LVAs were significantly older, were more likely to be female, had a higher CHA2DS2-VASc score, had larger LA volumes, and had a lower LA total emptying fraction (TEF). In multivariate analysis, only LA TEF [odds ratio (OR) 0.885, 95% confidence interval (CI) 0.846-0.926, P < 0.001] and the CHA2DS2-VASc score (OR 1.507, 95% CI 1.115-2.038, P = 0.008) remained independently associated with the presence of LVAs. CONCLUSION: Left atrial TEF and the CHA2DS2-VASc score were independently associated with the presence of LVAs found during LA electroanatomical mapping. These findings may help to improve pre-procedural prediction of pro-arrhythmogenic LVAs and to improve peri-procedural patient management.
No takes yet. Share an insight, caveat, or question.
Löbe et al. (2023) conducted a cohort in Atrial Fibrillation (n=259). Left atrial total emptying fraction (LA TEF) was evaluated on Presence of low-voltage areas (LVAs) defined as bipolar voltage amplitudes ≤0.5 mV on electroanatomical mapping (OR 0.885, 95% CI 0.846-0.926, p=<0.001). Lower left atrial total emptying fraction and a higher CHA2DS2-VASc score independently predicted the presence of pro-arrhythmogenic low-voltage areas during left atrial electroanatomical mapping.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: