Answers are grounded in this paper and cite their sources.
Demonstrates improved thermal comfort and energy efficiency in shared classrooms, suggesting effective HVAC management.
Improving HVAC energy efficiency while maintaining collective thermal comfort remains challenging in multi-occupant shared indoor environments, where occupants differ in thermal sensation, activity level, clothing condition, and spatial distribution. This study develops and field-validates an integrated edge-cloud IoT framework that connects non-invasive occupant-state sensing, INT8 edge thermal-sensation inference, and group-comfort-oriented HVAC setpoint optimization for classroom-based shared spaces. The proposed system integrates localized temperature–humidity sensing, vision-derived occupancy, posture, and clothing estimation, cloud-based thermal sensation model training, and edge-deployed real-time control on a HUB 8735 ULTRA device. A 4-day model-training data collection campaign with structured questionnaires was first conducted to obtain occupants’ Thermal Sensation Votes (TSVs) as ground-truth labels. The trained model was compressed from Float32 to INT8 through post-training quantization and deployed on the edge device for real-time inference. Predicted individual TSV values were then transformed into a PPD-inspired TSV-derived dissatisfaction index and used to determine the HVAC setpoint through rolling-horizon group comfort optimization. A separate eight-school-day single-blind daily-block A/B field validation was conducted, with four validation days assigned to the proposed smart control strategy and four days assigned to a fixed 25 °C baseline. The validation dataset included 2194 valid TSV questionnaire responses, which were aggregated into 116 valid 30 min classroom sessions for statistical comparison. The proposed control achieved a session-level mean TSV of −0.13, compared with −0.66 under the baseline, with Welch’s t(100) = 11.2, p < 0.001 and Cohen’s d = 2.11. Daily HVAC energy use decreased from 2.61 to 2.32 kWh/day, corresponding to a cumulative reduction of 1.16 kWh, or 11.1%, over the validation period. These results support the short-term feasibility of the proposed classroom-level human-centric HVAC control framework. However, because the validation was limited to a short-term classroom setting without full weather/load normalization, longer multi-season and multi-room studies are required to further evaluate generalizability and long-term energy performance.
No takes yet. Share an insight, caveat, or question.
Chung et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: