Why the study?
To evaluate how common echocardiographic metrics of AS influence the proportion of patients categorized as having severe stenosis and considered for valve replacement.
Observational (n=807)
No
Absolute Event Rate: 42.6% vs 93.8%
p-value: p=<0.001
Patients with discordant echocardiographic indices of severe aortic stenosis, who are disproportionately female, are frequently under-characterized as having severe disease, potentially impacting their consideration for valve replacement.
Objective To evaluate how common echocardiographic metrics of aortic stenosis (AS) influence the proportion of patients who may be categorised as having severe stenosis and therefore considered for valve replacement. Methods Retrospective analysis was performed of all echocardiograms with aortic valve area (AVA) ≤1.2 cm 2 and peak jet velocity (V max ) ≥3 m/s from 1 December 2014 through 30 October 2017 at a single academic medical centre. Echocardiographic indices collected include AVA, V max , left ventricular ejection fraction, stroke volume and annotated aortic stenosis severity. Results Among 807 patients with AVA ≤1.2 cm 2 and V max ≥3 m/s (44.0% female, median age 74 years (IQR: 66–81)), 45.6% had V max ≥4 m/s, while 75.8% had AVA ≤1 cm 2 . 40.0% of patients had concordant indices (V max ≥4 m/s and AVA ≤1 cm 2 ), and 35.8% had discordant indices (V max <4 m/s and AVA ≤1 cm 2 ) of severe AS. Compared with those with concordant indices, patients with discordant indices were more commonly female (54.0% vs 44.3%, p<0.05) and less commonly characterised as severe (42.6% vs 93.8%, p<0.001). Patients with paradoxical low-flow, low-gradient severe AS by echocardiography were disproportionately female (61.5% vs 41.8%, p<0.001), and their disease was characterised as severe only 49.5% of the time. Conclusions Patients with discordant indices, who are disproportionately female, are commonly described in clinical echocardiography reports as having less than severe AS. Given the potential benefit of AVR in patients with AVA ≤1 cm 2 regardless of V max , this could have important clinical implications.
No takes yet. Share an insight, caveat, or question.
Raddatz et al. (2020) conducted an observational in Aortic stenosis (n=807). Discordant echocardiographic indices (Vmax <4 m/s and AVA ≤1 cm2) vs. Concordant indices (Vmax ≥4 m/s and AVA ≤1 cm2) was evaluated on Characterised as severe aortic stenosis in clinical reports (p=<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: