Key result
Echocardiographic variations in left ventricular outflow tract measurement of 1 standard deviation reclassified up to 67% of patients from severe to non-severe aortic stenosis.
Why the study?
Timing of aortic valve intervention depends on the accuracy and reproducibility of echocardiographic parameters, prompting assessment of AS haemodynamic subsets, their change over time, and echo parameter variability.
Almost half of patients with aortic stenosis have valve area/gradient discordance, and small variations in LVOT measurement can significantly reclassify AS severity, highlighting the need for careful scrutiny of echocardiographic data.
Answers are grounded in this paper and cite their sources.
LVOT variability may misclassify aortic stenosis severity; leaves open standardization of echocardiographic protocols.
Background Timing of aortic valve intervention is dependent on the accuracy and reproducibility of echocardiographic (ECHO) parameters. We aimed to assess haemodynamic subsets of aortic stenosis (AS), their change over time, and variability of ECHO parameters. Method This retrospective, longitudinal study compared sequential ECHO over 15 months to identify concordant or discordant aortic valve area (AVA) and mean pressure gradient (MPG) in order to determine the real world variability of echocardiographic indices. Results We included 143 patients with a mean age of 76.0 years. The median length of time between studies was 112 days (IQR 38–208). Initially, participants were classified as 9 (6.4%) mild, 47 (33.6%) moderate, and 84 (60.0%%) severe AS. In 80 (55.9%) AVA and MPG were concordant; stroke volume index (SVi) was < 35 mL/m 2 in 53 (74.6%). AS severity was downgraded in 29 (20.7%) patients. MPG was most consistent and AVA was the least consistent between successive investigations (intraclass correlation coefficients R = .86 and R = .76, respectively). Even small variations in left ventricular outflow tract (LVOT) measurement of 1 standard deviation reclassified up to 67% of participants from severe to non‐severe. Conclusion Almost half of patients with AS have valve area/gradient discordance. Variations in LVOT diameter measurement commensurate with clinical practice reclassified AS severity in up to two‐third of cases. Change in AS severity should only be accepted following careful scrutiny of all available ECHO data.
No takes yet. Share an insight, caveat, or question.
Bray et al. (2021) studied this question. Echocardiographic variations in left ventricular outflow tract measurement of 1 standard deviation reclassified up to 67% of patients from severe to non-severe aortic stenosis.