Answers are grounded in this paper and cite their sources.
Prospective cross-sectional study compares dorsal hoof wall thickness and ratios using CT and radiographic methods, indicating measurement differences.
Summary Background No comparison of radiographic and computed tomographic (CT) dorsal hoof wall (DHW) thickness and DHW to the palmar length of the distal phalanx (DHWDP) ratio has been published. Radiographic measurements obtained with and without radiodense markers on the DHW have not been compared. Objective To compare radiographic (±radiodense marker), CT and anatomical measurements of the DHW thickness and DHWDP ratio. Study design Prospective cross‐sectional study. Methods Lateromedial radiographs (±radiodense marker on the DHW), midsagittal CT reconstructions and midsagitally cut anatomical specimens were obtained from 31 cadaver limbs. Lateromedial radiographs and CT images of 30 forelimbs of live horses were reviewed. DHW thickness (proximal, middle and distal) and the DHWDP were measured, and the DHWDP ratio was calculated. Measurements of different modalities were compared using the Wilcoxon‐signed rank test, one‐way repeated measures ANOVA or paired t ‐test. Results Radiographic measurements were greater than CT measurements at all measurement sites ( n = 60, p < 0.01), for example, middle DHW thickness: median 19.4 mm; interquartile range (IQR) 17.9, 20.6 mm vs. 15.6 mm; 14.6, 16.8 mm. In cadaver limbs ( n = 21), radiographic (middle DHW thickness: mean 19.5 ± standard deviation 2.1 mm) measurements were greater than both CT (16.3 ± 1.8 mm) and anatomical (16.9 ± 2.1 mm) measurements ( p < 0.01). Radiographic (0.27 ± 0.03), CT (0.26 ± 0.04) and anatomical (0.28 ± 0.04) DHWDP ratios differed ( p < 0.01). Using a marker resulted in marginally greater proximal (median 20.8; IQR 19.8, 22.1 vs. 20.3; 18.7, 21.9) and middle (19.9; 18.8, 22.0 vs. 19.5; 18.5, 21.7) radiographic DHW measurements ( n = 31, p < 0.01). Main limitations The position of reference images on different modalities might not have been identical. Conclusions Radiographic measurements were greater than CT; thus, radiographic reference ranges for DHW thickness cannot be applied to CT studies. The difference was smaller for DHWDP ratios than for DHW measurements. Using a marker on the DHW results in clinically insignificant overestimation of DHW thickness.
No takes yet. Share an insight, caveat, or question.
Obitayo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: