Answers are grounded in this paper and cite their sources.
Cadaveric study evaluates safety and accuracy of dry needling protocol targeting soleus muscle, suggesting high reliability.
INTRODUCTION: Despite the growing clinical use of dry needling, the anatomical accuracy and safety of ultrasound-unguided approaches to the soleus remain insufficiently standardized and validated. This study aimed to evaluate (i) the anatomical accuracy and safety of a standardized ultrasound-unguided dry needling protocol targeting the mid-third of the soleus, (ii) intra- and inter-rater reliability of key procedural outcomes, and (iii) agreement between ultrasound imaging and cadaveric dissection as validation methods for needle placement. METHODS: An experimental cross-sectional cadaveric study was conducted on five fresh-frozen human cadavers (10 lower limbs), yielding 24 dry needling events. Two physiotherapists with different levels of dry needling experience (intermediate: 5 years; advanced: >10 years) performed the protocol independently. A blinded sonographer assessed needle tip location and quantitative safety margins using high-resolution ultrasound. Anatomical dissection was subsequently performed to confirm final needle placement in a subset of approaches. Outcomes included soleus placement accuracy, septum puncture (lateral and posterior/deep), and neurovascular/vascular compromise. Reliability was assessed using percentage agreement and Cohen's kappa. RESULTS: Accurate needle placement within the soleus was achieved in 22/24 procedures (91.7%), with 2 failures (8.3%), both performed by the intermediate-experience physiotherapist. Lateral septum puncture occurred in 5/24 cases (20.8%), and posterior/deep septum puncture in 3/24 cases (12.5%). No puncture of the tibial neurovascular bundle or vascular structures was observed (0%). Intra-rater agreement for the advanced physiotherapist was 100% across dichotomous outcomes. Inter-rater agreement was 80% for soleus accuracy and overall procedural success. Ultrasound imaging and cadaveric dissection demonstrated 100% agreement across accuracy and safety outcomes in the advanced physiotherapist approaches. CONCLUSIONS: In this cadaveric model, a standardized ultrasound-unguided dry needling protocol targeting the soleus achieved high anatomical accuracy with no neurovascular injury, and showed excellent agreement between ultrasound and dissection for the advanced operator.
No takes yet. Share an insight, caveat, or question.
Sánchez-Montoya et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: