Answers are grounded in this paper and cite their sources.
Liver surgery has entered the era of precision surgery. Therefore, how to optimize the resection of lesions and reduce the unnecessary time of liver ischemia and hypoxia have become the focus. A total of 11 patients who underwent fluorescence laparoscopic liver mass resection and preoperative three-dimensional (3D) reconstruction between August 2018 and July 2020 were evaluated. Liver cirrhosis occurred in 3 patients. The mean intraoperative blood loss was 166.8 ± 105.7 mL. The average length of the operation time was 152.0 ± 45.3 minutes. The average intraoperative hilar occlusion time was 9.3 minutes (except for hilar cholangiocarcinoma). The liver function of all patients, except patients with hilar bile duct carcinoma, returned to the preoperative level at 72 hours, and no serious complications occurred. 3D reconstruction combined with fluorescence laparoscopic imaging is safe and effective for precision liver resection.
No takes yet. Share an insight, caveat, or question.
Ni et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: