Key result
Acute 0-G induced by parabolic flight increased cardiac output by 1.7 ± 0.4 l/min in seated subjects (P<0.001), which was reduced to 0.8 ± 0.4 l/min (P=0.028) with venous thigh-cuff inflation.
Why the study?
What are the mechanisms of increased cardiac output during acute weightlessness in humans?
What are the mechanisms of increased cardiac output during acute weightlessness in humans?
Effect estimate: 1.7 ± 0.4 l/min
p-value: p=<0.001
Blood from vascular beds above the legs accounts for about half of the increase in cardiac output during acute weightlessness in seated humans, with the remainder driven by increased heart rate.
Informs CO regulation mechanisms in acute weightlessness; leaves open applicability to sustained microgravity or clinical orthostasis.
Based on previous water immersion results, we tested the hypothesis that the acute 0-G-induced increase in cardiac output (CO) is primarily caused by redistribution of blood from the vasculature above the legs to the cardiopulmonary circulation. In seated subjects (n = 8), 20 s of 0 G induced by parabolic flight increased CO by 1.7 ± 0.4 l/min (P < 0.001). This increase was diminished to 0.8 ± 0.4 l/min (P = 0.028), when venous return from the legs was prevented by bilateral venous thigh-cuff inflation (CI) of 60 mmHg. Because the increase in stroke volume during 0 G was unaffected by CI, the lesser increase in CO during 0 G + CI was entirely caused by a lower heart rate (HR). Thus blood from vascular beds above the legs in seated subjects can alone account for some 50% of the increase in CO during acute 0 G. The remaining increase in CO is caused by a higher HR, of which the origin of blood is unresolved. In supine subjects, CO increased from 7.1 ± 0.7 to 7.9 ± 0.8 l/min (P = 0.037) when entering 0 G, which was solely caused by an increase in HR, because stroke volume was unaffected. In conclusion, blood originating from vascular beds above the legs can alone account for one-half of the increase in CO during acute 0 G in seated humans. A Bainbridge-like reflex could be the mechanism for the HR-induced increase in CO during 0 G in particular in supine subjects.
No takes yet. Share an insight, caveat, or question.
Petersen et al. (2011) studied Acute weightlessness (n=8). Acute 0-G induced by parabolic flight vs. Venous thigh-cuff inflation was evaluated on Increase in cardiac output (CO) (1.7 ± 0.4 l/min, p=<0.001). Acute 0-G induced by parabolic flight increased cardiac output by 1.7 ± 0.4 l/min in seated subjects (P<0.001), which was reduced to 0.8 ± 0.4 l/min (P=0.028) with venous thigh-cuff inflation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: