A compact liquid hydrogen target system has been developed for the Silicon Tracker for RAdioactive nuclei Studies at SAMURAI Experiments (STRASSE) at the RIKEN Nishina Center. This target, designed for proton-induced quasi-free scattering measurements in inverse kinematics, features a customizable cylindrical cell with a volume up to 125 mL which increases the reaction rate/luminosity, and thin Mylar walls to minimize the protons’ angular straggling. The cryogenic system, operated at 20 K, is optimized for rapid cool-down ( ≤ 5 h) and empty-target measurements, avoiding long experimental dead time. This new setup will allow for high-precision studies of nuclear structure using both missing-mass and in-flight prompt γ -ray spectroscopy techniques at the RIBF facility.